385 V SPD Power Surge Protection Device 25ka Din Rail AC House Protector

Brand Name:BRITEC
Certification:CE
Model Number:BR-25GR 1+1
Minimum Order Quantity:100 Piece/Pieces
Delivery Time:Shipped in 15 days after payment
Payment Terms:L/C, D/A, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Address: Block 1 , BoTongHuiGu industrial Park, Yueqing, Zhejiang ,China 325600
Supplier`s last login times: within 34 hours
Product Details Company Profile
Product Details

385v SPD Surge Protective Device 25ka Din Rail AC Whole House Protector


385 V SPD Power Surge Protection Device Features:


• Surge arrestors.
• High arresting capacity up to 25 kA (10/350μs).
• Visual status display.
• Simple standard rail mounting.
• Labeled connections

385 V SPD Power Surge Protection Device Technology characteristic:


BR-25GR 1+1
SPD classification according to EN61643-11Type 1 + Type 2
SPD classification according to IEC61643-11Class I + Class II
Max. continuous operating a.c. voltage Uc385V
Lightning impulse current (10/350us) (L-N / N-PE) Iimp25kA / 50kA
Nominal discharge current (8/20us) (L-N / N-PE) In25kA / 50kA
Maximum discharge current (8/20us) (L-N / N-PE) Imax100kA
Voltage protection level (L-N / N-PE) Up≤2.0kV
Follow current extinguishing capability a.c. lfi5kA rms
Max. backup fuse315A gG
Response time tA≤100ns
Operating temperature range Tu-40℃—80℃
Cross-section area (Min.)4mm2
Cross-section area (Max.)35mm2
For mounting on35mm Din rail
Enclosure materialThermal plastic UL94-V0
Degree of protectionIP20

Dimension:



385 V SPD Power Surge Protection Device Application:

Usable in systems with lightning protection class 1+2.


Noted:


• Before installing, you must cut off the power supply, don't operate in the charge state.
• Please connect with the installation diagram, the wrong connection is unallowable.
• After the installation is finished, turn on the switch of automatic circuit breaker (or fuse), to check whether the working state is normal or not.
• In the period of using the lightning proof module, view the fault display window is red, this means the lightning proof module has the fault, and you shall repair or change it in time.
• The parallel power lightning proof module shall be installed in parallel, the wire shall be short, thick and straight, connected firmly and reliably.
Certification:


Workshop:



FAQ:


Q1. Can I have a sample order for lightning arrester?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.


Q2. What about the lead time?
A: Sample needs 7 days, mass production time needs 20 days for order quantity.


Q3.Do you have any MOQ limit for lightning protection order?
A: Low MOQ, 100pcs.


Q4. How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 7 days to arrive. Airline and sea shipping also optional.


Q5: Do you offer guarantee for the products?
A: Yes, we offer 2 years warranty to our products.