| Capacity | 450 ml |
| charge mode | TYPE-C Port |
| Size/Weigh | 67*245mm/300g |
| External buttons | capacitive touch button |
| Material | 304 stainless steel,PP polypropylene |
| Charge time | 2 hours |
| Running time | About 40 times |
| Sterilization time | 1.5 min |
| Package content | Deep ultraviolet sterilization cup, TYPE-C data cable and product instruction |
User Manual:
1. Charge it before using.
2. Pour proper amount of water into the cup, then cover and tighten
the lid.
3. Touch the "Switch" button for 3 times to get the UVC LED light
up.
Deep ultraviolet sterilization schedule | |||
| Microorganism | 5LOG sterilization( 99.99%) | ||
Flux required (μW sec/cm² ) | Time required (seconds) | ||
| Bacteria/viruses | 5mW | 100mW | |
| Anthrax spores | 46200 | 35 | 1.75 |
| Escherichia coli | 6600 | 5 | 0.25 |
| Clostridium tetani | 22000 | 16.7 | 0.83 |
| Corynebacterium diphtheriae | 6510 | 4.93 | 0.25 |
| Typhoid fever | 4100 | 3.1 | 0.16 |
| Mycobacterium tuberculosis | 10000 | 7.6 | 0.38 |
| Gonorrhoea | 8500 | 6.4 | 0.32 |
| Salmonella | 7600 | 5.8 | 0.29 |
| Salmonella typhi of rats paratyphoid | 6100 | 4.6 | 0.23 |
| Dysentery | 4200 | 3.2 | 0.16 |
| Comma vibrio - cholera | 6500 | 4.9 | 0.25 |
| Infectious hepatitis | 8000 | 6.2 | 0.31 |
| Influenza | 6600 | 5 | 0.25 |
| Poliomyelitis | 6600 | 5 | 0.25 |
Troubleshooting
| Trouble reason | Examination | Handling methods |
Leakage | Is the lid tight? | Tighten the lid |
| Please check whether the waterproof ring is installed correctly? | Match the waterproof ring with the lid | |
| Is there any foreign matter on the surface of waterproof ring? | Removal of foreign bodies on the surface of waterproof ring | |
| Cannot turn on | Check if the battery is running out? | Please charge |