U-1000 R2V cable (also known as XV cable) and U-1000 RVFV cable
(also known as XAV cable) are rigid unarmoured power and control
cables used for the supply of electricity in a wide range of
semi-industrial and industrial applications with a voltage rating
of 600/1000V. This including lighting remote control and
telecontrol installation systems, and other electrical devices.
This range is manufactured in accordance with French Norms (U-1000
R2V: NF C 32-322 / U-100 RVFV: NF C 32-321).
The U-1000 R2V cable can be fixed on cable trays, within conduits
or to walls. The U-1000 RVFV is constructed with additional two
layers of steel tape armouring and so can also be used outdoors and
in direct burial installations or where additional protection
against mechanical stresses is required. The U-1000 RVFV is not
recommended for burial in areas that are flooded for more than two
months per year or in trenches used as drains.
U-1000 R2V XV | U-1000 RVFV XAV | |
---|---|---|
Conductor | 1.5mm2 to 4mm2: Solid copper (Class 1) 6mm2 and above: Stranded copper (Class 2) | |
Insulation | Cross-linked Polyethylene (XLPE) | |
Inner sheath | Polyvinyl Chloride (PVC) | |
Armour | - | Two steel tapes |
Outersheath | Flame retardant PVC | PVC |
The smaller sizes are also available with a stranded copper (Class
2) conductor upon request. Cables are available with 2-core,
3-core, 3-core plus earth, 4-core, 5-core and 7-core copper
conductors.
The R2V cable has a temperature rating of -10oC to +50oC during installation, before broadening to -25oC to +90oC when fixed. The RVFV has a range of -10oC to +60oC.
Class 2 stranded conductors are available on all sized cables on
request.
No. | CorexSize mm2 | Min. Conductor Stranding No. | Insulation nominal thickness mm | Outer Sheath nominal thickness mm | Approx. cable dia. mm | Approx. Cable Weight kg/km | Max. conductor DC resistance at 20 ℃ Ohm/km |
1 | 4x25 | 7 | 0.9 | 1.8 | 23.1 | 1182 | 0.727 |
2 | 5x16 | 7 | 0.7 | 1.8 | 21.6 | 977 | 1.15 |
3 | 5x10 | 7 | 0.7 | 1.8 | 18.8 | 667 | 1.83 |
4 | 5x6 | 7 | 0.7 | 1.8 | 16.3 | 446 | 3.08 |
5 | 5x4 | 1 | 0.7 | 1.8 | 14.0 | 322 | 4.61 |
6 | 5x2.5 | 1 | 0.7 | 1.8 | 12.7 | 237 | 7.41 |
7 | 3x4 | 1 | 0.7 | 1.8 | 12.0 | 220 | 4.61 |
8 | 3x2.5 | 1 | 0.7 | 1.8 | 11.4 | 184 | 7.41 |
No. | CorexSize mm2 | Min. Conductor Stranding No. | Insulation nominal thickness mm | Outer Sheath nominal thickness mm | Approx. cable dia. mm | Approx. Cable Weight kg/km | Max. conductor DC resistance at 20 ℃ Ohm/km |
1 | 4x240 | 34 | 1.7 | 2.8 | 52.6 | 9543 | 0.0754 |
2 | 4x120 | 18 | 1.2 | 2.3 | 37.6 | 4819 | 0.153 |
4 | 4x70 | 12 | 1.1 | 2.0 | 30.0 | 2876 | 0.268 |
5 | 4x50 | 6 | 1.0 | 1.9 | 25.8 | 2079 | 0.387 |