Home /Industry Laser Equipment /

Air Conditioner Motor Testing Machine Remote Control For Acceptance Testing

Air Conditioner Motor Testing Machine Remote Control For Acceptance Testing

Brand Name:AIP
Model Number:AIP89XX
Minimum Order Quantity:1 set
Delivery Time:45 working days
Place of Origin:China
Price:Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Qingdao Shandong China
Address: Building B-3, Liando U Valley, No. 780 Baoyuan Road, Chengyang High-tech District, Qingdao, China
Supplier`s last login times: within 48 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Air Conditioner Motor Testing Machine / Acceptance Testing Of Electric Motor


1. Tested product: air conditioner motor

Application: air conditioner production



2. Product features

High performance: compatible to test Hipot, insulation resistance, surge, winding resistance, rotation, no-load and stall. Easy-to-maintain: support intelligent self-diagnose, remote control failure diagnosis and online software upgrading.Modular design: independent test module design, all the test items are separately. Multiple languages are available to meet the requirements of customers all around the world.


3. Technical specifications

Insulation resistance
output voltage setting range/precisionDC 500V/1000V ±(2%×setting value+10V)
insulation resistance testing range/precision

1~500MΩ

≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ)

insulation resistance alarm setting rangeMax: 0~500MΩ; Min: 1~500MΩ
test time range/resolution0.5~999s 0.1s/step
AC Hipot
test time range/resolution0.5~999.9s 0.1s/step
Output voltage setting range and precisionAC 200~3000V ±(2%×setting value+10V)
breakdown current testing range/precision0.10~20.00mA ±(2%×display value+0.05 mA)
Hipot current presetting alarm rangeMax:0.10~20.00mA;Min:0.00~20.00mA
Surge
output voltage setting range/precision500~3000V ±(3%×display value+8V)
sampling frequency100MHz
waveform comparison

area, area difference, corona and phase

3 waveforms displayed in the testing interface

DC winding resistance test
testing range and precision10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set.
test time range/resolution

0.5~999s 0.1s/step


temperature compensation functionYes
temperature probe/rangeDS18b20 -10.0℃~+50.0℃
precision±0.5°C(range: -10℃~+50℃)
Low voltage start
voltage testing range and precisionAC:30~500V ±(0.5%×display value+1 words)
current testing range and precisionAC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision0.6-1500W ±(0.5%×display value+5 words)
Stall
voltage testing range and precisionAC:30~500V ±(0.5%×display value+1 word)
current testing range and precisionAC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision0.6-1500W ±(0.5%×display value+5 words)
No-load
voltage testing range and precisionAC:30~500V ±(0.5%×display value+1 word)
current testing range and precisionAC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision0.6-1500W ±(0.5%×display value+5 words)
Direction of rotation
rotationCW, CCW, still

4. Test procedures:

  1. Set the test sequence and parameters range as to the stator parameters and establish a new model for this type of stator (The model of one stator type needs to be established only for the first time)
  2. Put the tested stator on the test bench and clamp it
  3. Sliding cover to start the test and the “in-test” indication light is on.
  4. All the items will be tested in sequence. The operator is not allowed to touch the stator during the test.
  5. Pass or fail signal will be triggered after completing the test.
  6. Take out the tested stator and continue to test next one from step 2.
China Air Conditioner Motor Testing Machine Remote Control For Acceptance Testing supplier

Air Conditioner Motor Testing Machine Remote Control For Acceptance Testing

Inquiry Cart 0