No - Load / IR Electrical Test Equipment Multipurpose Multiple Languages Available

Brand Name:AIP
Model Number:AIP89XX
Minimum Order Quantity:1 set
Delivery Time:45 working days
Payment Terms:L/C, T/T
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Qingdao Shandong China
Address: Building B-3, Liando U Valley, No. 780 Baoyuan Road, Chengyang High-tech District, Qingdao, China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Multifunction Motor Testing Machine, No-Load, Stall, Hipot, IR, Surge, Resistance Test


1. Test: No-load, stall, Hipot, insulation resistance, surge and winding resistance


2. Technical specification

AC Hipot
test time range/resolution0.5~999.9s 0.1s/step
Output voltage setting range and precisionAC 200~3000V ±(2%×setting value+10V)
breakdown current testing range/precision0.10~20.00mA ±(2%×display value+0.05 mA)
Hipot current presetting alarm rangeMax:0.10~20.00mA;Min:0.00~20.00mA
Surge
output voltage setting range/precision500~3000V ±(3%×display value+8V)
sampling frequency100MHz
waveform comparison

area, area difference, corona and phase

3 waveforms displayed in the testing interface

Direction of rotation
rotationCW, CCW, still
DC winding resistance test
testing range and precision10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set.
test time range/resolution

0.5~999s 0.1s/step

temperature compensation functionYes
temperature probe/rangeDS18b20 -10.0℃~+50.0℃
precision±0.5°C(range: -10℃~+50℃)
Insulation resistance
output voltage setting range/precisionDC 500V/1000V ±(2%×setting value+10V)
insulation resistance testing range/precision

1~500MΩ

≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ)

insulation resistance alarm setting rangeMax: 0~500MΩ; Min: 1~500MΩ
test time range/resolution0.5~999s 0.1s/step
No-load
voltage testing range and precisionAC:30~500V ±(0.5%×display value+1 word)
current testing range and precisionAC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision0.6-1500W ±(0.5%×display value+5 words)
Stall
voltage testing range and precisionAC:30~500V ±(0.5%×display value+1 word)
current testing range and precisionAC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision0.6-1500W ±(0.5%×display value+5 words)
Low voltage start
voltage testing range and precisionAC:30~500V ±(0.5%×display value+1 words)
current testing range and precisionAC:0.02~5.0A ±(0.5%×display value+2 words)
power testing range and precision0.6-1500W ±(0.5%×display value+5 words)

3. Configuration list

No.NameSpecificationUnit
1Master unitCustomizedSet
2Test benchCustomized clampsSet
3Test softwareSave the test requirements, data and control the test processSet
4CabinetEasy to be moved with foot wheelsSet

4. Test procedures

  • Set the test sequence and parameters range as to the stator parameters and establish a new model for this type of stator (The model of one stator type needs to be established only for the first time)
  • Put the tested stator on the test bench and clamp it
  • Sliding cover to start the test and the “in-test” indication light is on.
  • All the items will be tested in sequence. The operator is not allowed to touch the stator during the test.
  • Pass or fail signal will be triggered after completing the test.
  • Take out the tested stator and continue to test next one from step 2.