2km Modbus RTU Module I O Wireless ON OFF Control One Master To 8 Slaves

Brand Name:Lensen
Model Number:LS-RDIO0202+LS-R324
Minimum Order Quantity:9pcs
Delivery Time:2-7 days
Payment Terms:T/T, Western Union
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 701, Yongchang Building, Xicheng Industrial Zone, Xixiang, Bao'an District, Shenzhen, China 518126
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

2km Wireless Modbus RTU I O Module Wireless ON OFF Control One Master To 8 Slaves


1. LS-R324 General Introduction

LS-R324 wireless DTU whose transmission distance reaches 3km LOS, supports wireless communication between Siemens S7-200, S7-300 series PLC, Schneider PLC, Mitsubishi PLC, ABB PLC etc. LS-R324 supports Modbus protocol, including Modbus ASCII and Modbus RTU protocol, PPI protocol.


LS-R324 DTU can also connect with VFD, HMI, PC for wireless communication. It supports point to point, point to multi-points wireless data transmission. Wireless solution has the advantage of keep users from wiring cables in dangerous field, easy to set up, no need program knowledge. It is a reliable and competitive solution.


2. Application Field

  • Pressure, flow rate, temperature etc data collections, wireless transmission and control in water/waste water treatment field
  • Wind speed, rainfall, humidity etc data collection, wireless transmission and control at whether monitoring station
  • Temperature, humidity, concentrations of CO2 etc data collection, wireless transmission and control in agriculture greenhouse
  • AGV wireless monitoring and control
  • Other kinds of OEM equipment wireless data collection and transmission
  • Wireless communication between PLC and sensors on Chemical machinery and equipment, oil field.

3. Technical specification

Frequency433MHz or 450MHz, 470MHz
Power Output1W(3000m LOS)
Protocol supportStandard Modbus RTU protocol or user-defined protocol
Power supply9-36V DC usually use 24V DC or 12V DC
InterfaceRS-485(default)or RS232 or USB
Channel No.15 channel, use DIP to change
AntennaFree sucker antenna with 1.5m cable(buy 5.5dBi sucker antenna)
Temperature-35℃~+75℃ (industrial)
Dimension175×115×32(mm) exclude antenna
Fix methodScrew

4.LS-RDIO0202 Parameter

Parameter
Power output:1W (or 100mW version)
Power supply:9V-30V (usually choose 24V DC or 12V DC)
Control distance:3km (or 1km version)
Baud rate:1200bps
Receiving sensibility:-123dBm@1200bps, -118dbm(9600bps)
Networking
Networking:Point to point and point to multipoint
Protocol:Modbus RTU protocol
Port Description
Input:2 active inputs (passive customize), isolated
Output:

2 passive relay outputs, isolated

contact max load AC250V/5A,DC30V/5A

(active outputs 0-5V customize)

Communication portRS485 (wireless RS485 customize)
Current
Transmit current:<600mA (or 100mA version)
Receiving current:<50mA (or 20mA version)
General
Frequency:433MHz, 400, 450, 470 or other band
Channel No:16 channels, can change via DIP switch
Physical Properties
Dimension:115×90×40(mm)
Antenna Connector:SMA,vehicle antenna with 1.5m cable
Temperature:-35℃~+75℃( industrial)
Mounting method:Standard 3.5 inch industrial guild rail