Add to Cart
CL2 Chlorine Gas Concentration Single Gas Detector Level Detector
With Alarm
Funtions:
1. Monitor the CL2 Chlorine gas in environment or pipeline.
2. With self-calibration and zero calibration function, makes the
detection more accurate and reliable.
3. With temperature compensation, this is able to realize gas
concentration compensation under conditions of different
temperatures.
4. Infrared ray controller can remote control alarm point settings,
zero calibration, and address modification. (optional)
5. Can output one or two on-off signals, can drive ventilator or
solenoid valve and other external devices. (optional)
6. Working Voltage:24V DC
7. Case: die-cast aluminum
Specification
Gas detected | CL2, Chlorine | ||
Detection principle | Electrochemistry | ||
Install method | Wall-mounted, piping type, flow-type (according to the detected environment) | ||
Measure range | 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm, 0-200ppm, 0-250ppm | ||
Resolution | 0.001ppm, 0.01ppm, 0.1ppm | ||
Precision | ≤± 1% FS or ± 2-3% FS | ||
Signal output | 4-20mA, 0-5V, RS485, relay(optional) | ||
Response time | ≤10S | Recovery time | ≤10S |
Repeatability | ≤±1% | Linearity error | ≤±1% |
Zero shift | ≤±1%(FS/year) | Display | High-light nixie tube display |
Connection mode | G1/2 external thread explosion-proof flexible pipe | Unit | ppm |
Temperature | -20 to 50°C | Humidity | 0-95%RH |
Explosion-proof | Ex dⅡCT6 | Degree of protection | IP65 |
Alarm | Sound, light | Operating time | 24H |
Dimensions | 180*150*90mm | Weight | ≤2kg |
Characteristics:
1. Standard equipped with three-wire system 4-20mA analog output;
relay output; RS485 output.
2. Unique infrared ray control function, which can non-contacted
control the device.
3. Being compatible with all kinds of controlled alarms, PLC, DCS
and other control system, can be remote monitored.
4. Explosion-proof design, fast, reliable and stable.
5. Explosion-proof grade: Ex dⅡCT6
6. With self-calibration function, and three standard keys will be
used to realize on-site maintenance.
7. Detachable probe/gas cell: It is very easy to calibrate and replace sensor
Services:
1. For all our customers, we guarantee one year warranty, and
life-long maintenance.
2. All inquiries will be replied in 24 hours.
3. We will provide technical support, our engineers will help to
solve the problems you met.
4. We can provide OEM service.
5. We are manufacturer with own factory, welcome to visit our
factory.
6. All products will be well checked and well packed before
shipment, and qualification certificatewill be provided.