Add to Cart
110kw factory sale 40 G20 industrial burner gas grill used oil burner annealing furnace oil burning heater
Industrial burner Technical performance
The YX series boiler burner oil furnace are designed with
electromechanical integration, and the components used are strictly
screened and synchronized with the international:
1. Lightweight aluminum alloy fan parts
2. High performance centrifugal fan
3. Using 304 stainless steel pipeline to improve the life of the
machine
4. Sliding burner with fixture and steel flame disk
5. Adjust the flow rate of gas and damper at the rated gas pressure
to achieve accurate air-fuel ratio, making the burner more
efficient, more energy-saving and safer.
Industrial burner Control method: The burner is divided into
single-stage, double-stage, double-stage progressive and
proportional adjustment to meet the needs of different user
numbers.
1. Single-stage: on/off two working conditions.
2. Double-stage: The burner output is divided into three
conditions: shut-off, small fire and big fire. The burner
automatically switches between large and small fires under the
control of a temperature or pressure switch.
3. Two-stage progressive type: The two-stage progressive burner can
smoothly transition between large and small fires, making the
air/burn ratio extremely accurate over the entire range
(minimum-maximum).
4. Proportional adjustment: Proportional-regulated burners are
suitable for combustion equipment with high fluctuations in load
and high control requirements. The treatment of the burner can be
matched with the equipment load and can be continuously adjusted
throughout the combustion range.
Industrial burner data sheet for reference :
Light Oil Burner YX5-YX350DSG BALTUR DESIGN | ||||||||
MODEL | FUEL COMBUSTION | BUR NER OUTPUT | MAIN SUPPLY | POWER | CONTROL METHOD | |||
KG/HR | KW | |||||||
MIN | MAX | MIN | MAX | W | KV | |||
SINGLE STAGE BURNER | ||||||||
YX5(ST120) | 2 | 5.6 | 24 | 66 | 220V | 110 | 2*5 | S |
YX6 | 2.7 | 6.3 | 24 | 66 | 220V | 110 | 2*5 | S |
YX10 | 5.2 | 10 | 60.5 | 116.6 | 220V | 110 | 2*5 | S |
YX10 | 4.5 | 10 | 54 | 118.6 | 220V | 120 | 2*5 | S |
YX20 | 8 | 20 | 95 | 237 | 220V | 180 | 2*5 | S |
YX14 | 7.5 | 14.5 | 88.5 | 171 | 220V | 150 | 2*5 | S |
YX18 | 7.6 | 18 | 90 | 213 | 220V | 370 | 2*5 | S |
YX26 | 13 | 26 | 154 | 308 | 220V | 370 | 2*5 | S |
YX35 | 15 | 33 | 178 | 391.4 | 220V | 370 | 2*5 | S |
YX34 | 15 | 32 | 178 | 380 | 380V | 370 | 2*5 | S |
YX40 | 20 | 45 | 237 | 534 | 380V | 550 | 2*5 | S |
TWO STAGE BURNER | ||||||||
YX14DSG | 7.5 | 14.5 | 88.5 | 171 | 220V | 150 | 2*5 | T |
YX18DSG | 10.5 | 22 | 124.5 | 261 | 220V | 370 | 2*5 | T |
YX26DSG | 13 | 26 | 154 | 308 | 220V | 370 | 2*5 | T |
YX35DSG | 15 | 33 | 178 | 391.4 | 220V | 370 | 2*5 | T |
YX34DSG | 15 | 32 | 178 | 380 | 380V | 370 | 2*5 | T |
YX40DSG | 20 | 45 | 237 | 534 | 380V | 550 | 2*5 | T |
YX55DSG | 28 | 55 | 332 | 562 | 380V | 1100 | 2*5 | T |
YX75DSG | 35 | 75 | 415 | 880 | 380V | 1500 | 2*5 | T |
YX100DSG | 45 | 100 | 533 | 1185 | 380V | 2200 | 2*5 | T |
YX120DSG | 40 | 140 | 474 | 1660 | 380V | 2200 | 2*5 | T |
YX180DSG | 60 | 180 | 712 | 2135 | 380V | 3000 | 2*5 | T |
YX250DSG | 74 | 270 | 873 | 3185 | 380V | 7500 | 2*5 | T |
YX300DSG | 110 | 325 | 1304 | 3854 | 380V | 7500 | 2*5 | T |
YX350DSG | 115 | 350 | 1346 | 4151 | 380V | 7500 | 2*5 | T |
BY LIGHT DIESEL OIL BURNER RIELLO DESIGN | ||||||||
Burner model | Suitable for boiler (TON/H) | Burner thermal power (KW) | Burner thermal power (MCAL/H) | Oil Consume (KG/H) | Fan power (KW) | Applicable fuel | Adjust Method | |
BY6 | 1 | 300-1186 | 255-1020 | 25-100 | 1.5 | DIESEL OIL KEROSENE OIL 0#diesel 11.86Kwh/kg 1.02x104kcal/h | Z-two stage T-three stage R-Mechanical ratio control | |
BY10 | 1.5 | 600-1900 | 520-1642 | 51-160 | 3 | |||
BY15 | 2 | 770-2750 | 663-2377 | 65-232 | 4 | |||
BY20 | 3 | 890-3100 | 765-2683 | 75-261 | 7.5 | |||
BY30 | 4 | 1100-4100 | 949-3539 | 93-346 | 10 | |||
BY35 | 5 | 1300-5260 | 1122-4549 | 110-444 | 12 | |||
BY40 | 6 | 1150-6100 | 989-5273 | 97-514 | 13.5 | |||
BY55 | 8 | 1900-8750 | 1642-7568 | 160-738 | 15 | |||
BY70 | 10 | 1900-10500 | 1642-9030 | 160-885 | 22 |