Horizontal Oil/ gas pressure hot water boiler for hotel electric water kettle boiler price
CWNS direct heating
1. The CWNS series is a horizontal internal combustion wet-back shell boiler. It consists of a shell, a furnace, a back-burning chamber, a front and rear smoke box, and a fire tube.
2. Small-sized straight furnace, large-sized corrugated furnace, enhanced heat transfer and high thermal efficiency.
3. The back-fired chamber adopts the butt welding process and the wet-back structure, which avoids the disadvantages of the back tube sheet being washed by the high-flux gas flushing weld to ensure the safe operation of the boiler.
4. The boiler is shipped from the factory, and various control systems such as touch screen, PLC program control, and ordinary computer are available.
5. The exterior is packaged in milky white color steel plate, which is beautiful and elegant.
6. Central hot water unit (indirect heating type) modular design: modular central hot water unit, which combines boiler, circulating water pump, valve, instrument, control system and other accessories and software into one module, installed in the factory Complete sets, in the form of units directly used in the heating system linkage system where needed. The function is extensible and meets the multi-faceted selective needs of users.
Features:
1. Adopting the normal pressure mode, the boiler is not under
pressure, and the safety factor is high, and there is no danger of
explosion.
2. Designed as a burner-type pyrotechnic tube boiler, the fuel is
burned by the burner in a micro-positive pressure in the furnace,
the high-temperature flue gas is radiated and heat-exchanged in the
furnace, and then enters the convective heat exchange of the
pyrotechnic tube, and finally passes through the upper cigarette
case. discharge.
3. The boiler body design of the boiler body adopts computer
optimized simulation design, which fully optimizes the size of the
boiler and makes the shape harmonious and beautiful.
4. The flue pipe is inserted with a baffle to slow down the flue
gas discharge speed, strengthen the heat exchange, ensure the heat
generated by the fuel combustion to heat the boiler water to the
greatest extent, and greatly improve the thermal efficiency of the
boiler.
5, equipped with imported brand burners, fully automatic program
control, high degree of automation, the fuel system provides the
fuel needed for combustion, the air supply system sends the
appropriate wind speed, air volume, the ignition system ignites the
mixture of air and fuel, the detection system Ensure stable and
safe combustion of the burner
6. The gap between the large diameter pipe and the large hole
bridge makes the scale coating thin and easy to clean in the same
time. Product map
7, the shell shell furnace large interlayer water jacket, the
boiler water capacity is large, can provide sufficient boiling
water.
8, with multiple safety protection: leakage protection means that
leakage automatically cuts off the power supply; overheat
protection means that when the boiler water temperature reaches the
alarm temperature, the burner is automatically stopped and an alarm
is issued; when the secondary overheat protection means that the
temperature of the boiler casing exceeds 105 °C, it is
automatically cut off. The secondary circuit, the boiler stops
working; the water level detection protection uses the
sophisticated water level electrode rod to monitor the water level
in real time, and the water level is lower than the upper limit
water level solenoid valve until the upper limit water level is
reached.
9, mechatronics design, small size, easy to install and transport.
10. The furnace is specially treated to ensure the water quality is
clean and hygienic.
11, the outer lining aluminum foil glass wool for insulation,
better insulation effect.
12, white color plate packaging, beautiful, clean and rust
resistant.
13. The water supply port is at the lower part, the solenoid valve
automatically replenishes water, and the boiling water in the
boiling water area takes water to eliminate the phenomenon of “hot
and cold water” and “thousand boiling water” to ensure that 100% of
the drinking water is pure boiling water. 14. The boiler can be
used in two machines, which can supply boiling water and provide
hot water.
Oil water boiler 0.35MW-14MW Oil Gas Fired hot water boiler technical datasheet
Main technical parameters of CWNS oil (gas) atmospheric pressure and pressure hot water boiler | |||||||||||||||
Project model | CWNS, WNS series hot water boiler | ||||||||||||||
Rated calorific value (MW) | 0.35 | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 5.6 | 7 | 8.4 | 10.5 | 12.6 | 14 | |
Working pressure (MPa) | Normal pressure / pressure | ||||||||||||||
Outlet water temperature (°C) | 85/115 | ||||||||||||||
Backwater temperature (°C) | 60/70 | ||||||||||||||
Boiler thermal efficiency (%) | 91—95 | ||||||||||||||
Feed water temperature (°C) | 20 | ||||||||||||||
Fuel consumption | Diesel (Kg/h) | 32 | 65.4 | 98 | 131 | 196.2 | 261.6 | 327 | 392.4 | 523.2 | 654 | 784.8 | 981 | 1177 | 1310 |
Heavy oil (Kg/h) | 34 | 69.5 | 105 | 139 | 208.5 | 278 | 347.5 | 417 | 556 | 695 | 864 | 1042.5 | 1251 | 1390 | |
Natural gas (m3/h) | 39.5 | 79.3 | 119 | 159 | 237.9 | 317.2 | 396.5 | 475.8 | 644 | 793 | 951.6 | 1189.5 | 1427.4 | 1586 | |
Liquefied gas (m3/h) | 14.2 | 29 | 43.5 | 58 | 87 | 116 | 145 | 174 | 232 | 290 | 348 | 435 | 522 | 580 | |
City gas (m3/h) | 84 | 168.5 | 253 | 337 | 505.5 | 674 | 842.5 | 1011 | 1348 | 1685 | 2022 | 2527.5 | 3033 | 3370 | |
Boiler transportation | Length (mm) | 2800 | 3500 | 4100 | 4500 | 4700 | 4550 | 5700 | 6300 | 7000 | 7200 | 7840 | 8100 | 8230 | 8250 |
Width (mm) | 1600 | 1600 | 1900 | 2000 | 2110 | 2210 | 2500 | 2600 | 2700 | 2800 | 2860 | 3100 | 3100 | 3400 | |
High (mm) | 2000 | 2100 | 2310 | 2360 | 2470 | 2580 | 2800 | 2900 | 3200 | 3300 | 3300 | 3400 | 3400 | 3550 | |
Total power consumption (KW) | 2.3 | 6.7 | 11 | 13.5 | 19 | 21 | 23.5 | 26 | 37 | 37 | 42 | 45 | 52 | 52 | |
Chimney diameter (mm) | 250 | 350 | 430 | 450 | 450 | 550 | 650 | 650 | 650 | 800 | 800 | 900 | 1200 | 1200 | |
Shipping weight (T) | 3.2 | 4.7 | 4.8 | 5.4 | 8 | 9.78 | 13.4 | 15.4 | 17.4 | 17.4 | 23.8 | 30 | 31.6 | 34.5 | |
Heating area (m2) | 3000 | 6000 | 900 0 | 1200 0 | 1800 0 | 2400 0 | 3000 0 | 3600 0 | 4800 0 | 6000 0 | 7200 0 | 900 00 | 1080 00 | 1200 00 | |
Water supply capacity (t) | 7 | 15 | 22 | 30 | 45 | 60 | 75 | 90 | 120 | 150 | 180 | 225 | 270 | 300 |
Oil water boiler Vocume hot water boiler
Project / model | ZKW0.7-85/60-Y(Q) | ZKW1.05-85/60-Y(Q) | ZKW1.4-85/60-Y(Q) | ZKW1.75-85/60-Y(Q) | ZKW2.1-85/60-Y(Q) | ZKW2.8-85/60-Y(Q) | ZKW3.5-85/60-Y(Q) | |
Heat medium water capacity (L) | 410 | 520 | 568 | 700 | 830 | 980 | 1250 | |
Rated calorific value (Mw/h) | 0.7 | 1.05 | 1.4 | 1.75 | 2.1 | 2.8 | 3.5 | |
Rated calorific value | 60 | 90 | 120 | 150 | 180 | 240 | 300 | |
Fuel consumption | Light diesel oil (Kg/h) | 64 | 96 | 128 | 160 | 192 | 256 | 320 |
Heavy oil (Kg/h) | 67.3 | 100 | 134 | 168 | 202 | 269 | 363 | |
Natural gas (m3/h) | 165 | 116 | 155 | 193 | 232 | 310 | 387 | |
City gas (m3/h) | 77 | 247 | 330 | 412 | 494 | 659 | 824 | |
Liquefied gas (m3/h) | 29 | 44 | 58 | 73 | 88 | 117 | 146 | |
Heat Exchanger | Material/structure | Stainless steel | ||||||
Working pressure (MPa) | 1 | |||||||
Heating | Maximum calorific value | 36 | 54 | 72 | 90 | 108 | 144 | 180 |
Warm water circulation | 36 | 54 | 72 | 90 | 108 | 144 | 180 | |
Pressure loss | 2.2 | 3 | 2 | 2.6 | 2.5 | 3.5 | 3.3 | |
Heating outlet (DN) | 65 | 80 | 80 | 100 | 125 | 125 | 133 | |
Heating area (m2) | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 30000 | |
Special for hot water | Maximum calorific value | twenty four | 36 | 48 | 60 | 72 | 96 | 120 |
Water supply capacity (m3/h) | 6 | 9 | 12 | 15 | 18 | twenty four | 30 | |
Hot water temperature | 50 | |||||||
Pressure loss | 2 | 0.6 | 1.5 | 1.8 | 1.5 | 1.8 | 2 | |
Water outlet diameter (DN) | 40 | 65 | 65 | 80 | 100 | 100 | 125 | |
Voltage | Voltage (V) | 220/380 | ||||||
Total power consumption | 2.2 (2.6) | 3.7 (4.1) | 5.0 (6.5) | 7.5(9) | 11 (2.5) | 15 (16.5) | 18.5(20) | |
Blower power consumption | 2.2 | 3.7 | 5 | 7.5 | 11 | 15 | 18.5 | |
Oil pump power consumption | 0.4 | 0.4 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | |
size | Chimney diameter (mm) | 350 | 350 | 400 | 450 | 500 | 550 | 600 |
Long (m) | 2700 | 3200 | 3400 | 4050 | 4700 | 4900 | 5500 | |
Width (m) | 1365 | 1365 | 1600 | 1600 | 1600 | 1800 | 2020 | |
High (m) | 2345 | 2400 | 2500 | 2580 | 2580 | 2630 | 2700 |