Add to Cart
1.05MW CST380 furnace oil fired boiler for Textile production line
The fuel gas hot water boiler for textile production line is small in size and covers a small area. Clean, low noise and low pollution make it a great choice for workshop factories.
Furnace oil fired boiler design:
The structure of the fuel hot water boiler is designed according to
normal pressure. The top is provided with atmospheric holes. The
boiler works under normal pressure and is away from the explosion
hazard. The boiler furnace body is optimized by computer
simulation, which fully optimizes the size of the boiler and makes
the shape harmonious and beautiful.
1. The CLHS vertical boiler adopts the burner under-burning mode.
The fuel is burned in the furnace under micro-positive pressure.
The high-temperature flue gas is radiated and exchanged in the
furnace, and then enters the convective heat transfer of the
pyrotechnic tube. Finally, it is discharged through the upper
casing. . The flue pipe is inserted with a baffle to slow down the
flue gas discharge speed, strengthen the heat exchange, ensure the
heat generated by the fuel combustion to heat the boiler water to
the greatest extent, and greatly improve the thermal efficiency of
the boiler;
2, CWNS horizontal Furnace oil fired boiler adopts full wet back
three-return structure, long flue gas flow, lower exhaust gas
temperature, full corrugated furnace setting, strong flame
disturbance, strong heat transfer coefficient, and effectively
prevent metal heat Expansion and contraction lead to a reduction in
equipment life; large-diameter pipe and large-hole bridge
clearance, so that the scale of the boiler is thin and easy to
clean in an equal time.
Furnace oil fired boiler 0.35MW-14MW, Oil Gas Fired hot water boiler technical datasheet
Main technical parameters of CWNS oil (gas) atmospheric pressure and pressure hot water boiler | |||||||||||||||
Project model | CWNS, WNS series hot water boiler | ||||||||||||||
Rated calorific value (MW) | 0.35 | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 5.6 | 7 | 8.4 | 10.5 | 12.6 | 14 | |
Working pressure (MPa) | Normal pressure / pressure | ||||||||||||||
Outlet water temperature (°C) | 85/115 | ||||||||||||||
Backwater temperature (°C) | 60/70 | ||||||||||||||
Boiler thermal efficiency (%) | 91—95 | ||||||||||||||
Feed water temperature (°C) | 20 | ||||||||||||||
Fuel consumption | Diesel (Kg/h) | 32 | 65.4 | 98 | 131 | 196.2 | 261.6 | 327 | 392.4 | 523.2 | 654 | 784.8 | 981 | 1177 | 1310 |
Heavy oil (Kg/h) | 34 | 69.5 | 105 | 139 | 208.5 | 278 | 347.5 | 417 | 556 | 695 | 864 | 1042.5 | 1251 | 1390 | |
Natural gas (m3/h) | 39.5 | 79.3 | 119 | 159 | 237.9 | 317.2 | 396.5 | 475.8 | 644 | 793 | 951.6 | 1189.5 | 1427.4 | 1586 | |
Liquefied gas (m3/h) | 14.2 | 29 | 43.5 | 58 | 87 | 116 | 145 | 174 | 232 | 290 | 348 | 435 | 522 | 580 | |
City gas (m3/h) | 84 | 168.5 | 253 | 337 | 505.5 | 674 | 842.5 | 1011 | 1348 | 1685 | 2022 | 2527.5 | 3033 | 3370 | |
Boiler transportation | Length (mm) | 2800 | 3500 | 4100 | 4500 | 4700 | 4550 | 5700 | 6300 | 7000 | 7200 | 7840 | 8100 | 8230 | 8250 |
Width (mm) | 1600 | 1600 | 1900 | 2000 | 2110 | 2210 | 2500 | 2600 | 2700 | 2800 | 2860 | 3100 | 3100 | 3400 | |
High (mm) | 2000 | 2100 | 2310 | 2360 | 2470 | 2580 | 2800 | 2900 | 3200 | 3300 | 3300 | 3400 | 3400 | 3550 | |
Total power consumption (KW) | 2.3 | 6.7 | 11 | 13.5 | 19 | 21 | 23.5 | 26 | 37 | 37 | 42 | 45 | 52 | 52 | |
Chimney diameter (mm) | 250 | 350 | 430 | 450 | 450 | 550 | 650 | 650 | 650 | 800 | 800 | 900 | 1200 | 1200 | |
Shipping weight (T) | 3.2 | 4.7 | 4.8 | 5.4 | 8 | 9.78 | 13.4 | 15.4 | 17.4 | 17.4 | 23.8 | 30 | 31.6 | 34.5 | |
Heating area (m2) | 3000 | 6000 | 9000 | 12000 | 18000 | 24000 | 30000 | 36000 | 48000 | 60000 | 72000 | 90000 | 108000 | 120000 | |