6 Ton Coal Fired Central Heating Boilers ASME Water Tube Package Boiler

Brand Name:YONGXING
Certification:ISO9001,ISO14001,SGS,BV
Model Number:DZL
Minimum Order Quantity:1set
Delivery Time:10-15days
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Active Member
Location: Zhoukou Henan China
Address: Develop area,Taikang County,Zhoukou City,Henan PR,China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

DZL 6 ton industrial automatic coal fired steam boiler with chain grate stoker


Introduction

1. The DZL series boiler is a horizontal three return fire tube boiler, and the combustion equipment is a chain grate.

2. The water-cooling wall on the left and right sides of the furnace is a radiant heating surface, the two wings of the furnace are convective heating surfaces, the convection heating surface of the threaded tobacco pipe is arranged in the drum, and the front and rear arches are made of a heat-resistant concrete integrally cast enamel. The outside of the boiler main body is a shield housing.

3. The fuel falls from the coal hopper the front part of the grate. As the grate runs, the coal undergoes preheating, retorting, ignition, and burning. The slag falls into the slag bucket, and is discharged from the furnace at any time by the slag removing machine.

5. The rear arch can form a vortex and air to fully mix, and heat the front arch to improve the fire condition.

6. The upper wing of the arch exits into the two-wing convection water wall bundle, enters the threaded pipe through the front smoke box, passes the economizer and the dust collector, led by the induced draft fan to the chimney.


Auxiliary Data

Parts Type

1. Chain Grate Travelling grates OR flake type chain grates
2. Induced Draft Fan GY1-18 4#Right 0°, Electromotor Y 132S-4B3
3. Forced Draft Fan 4-72-3.2A Right 315°, Electromotor Y 90L-2
4. Electric Pump JGGC2-8X13, Electromotor Y 90L-2
5. Govenor Stepless speed governor, Electromotor YCT112-4A
6. Ash Extractor Screw type, Electromotor Y 90S-6
7. Dust Collector Multi-tube XTD-1

Data sheet 1

ParameterData
Rated evaporation capacity6 ton/h
Rated working pressure1.25MPa
Rated steam temperature193℃
Water-supply temperature20℃
Boiler heating area216.4㎡
Grate area7.54㎡
Thermal efficiency80.32%
Exhaust temperature125℃
Boiler Water volume10.2m³
Dimension(L*W*H)7.42m*3m*3.67m

Data sheet 2

ModelDZL1-A IIDZL2-A IIDZL 4-A IIDZL8-A II
Rated evaporation capacity (T)1248
Rated working pressure (MPa)0.7/1.0/1.250.7/1.0/1.251.25/1.61.25/1.6
Rated steam temperature (℃)170/184/194170/184/194194/204194/204
Water-supply temperature(℃)20202020
Boiler heating area (㎡)57.4789.4124.9432.22
Grate area (㎡)2.73.455.910.81
Exhaust flue gas temperature (℃)120.7157167163.41
Thermal Efficiency (%)80.4278.479.779.36
Size (m)5.27*2.5*3.155.4*2.4*3.486.18*2.95*3.359.05*3.2*4.-


General standard

1. The boiler assembly shall be in accordance with ,2000 edition and JB/ t7985-2002, .
2. The boiler is designed according to normal pressure. The top of the furnace body is provided with an air outlet. The boiler runs without pressure and the combustion operation is safe and reliable. Atmospheric hot water boilers can be installed in any place where they are used, and are not subject to a wide range of annual inspection procedures, and have been rapidly developed in recent years.

Welcome inquiry more specifications if u need .

Quckly installed boiler
boiler modelUnitDZL1-0.7/1.0-AIIDZL2-0.7/1.0-AIIDZL4-0.7/1.25/1.6-AIIDZL6-1.25/1.6-AII
capacityton/h1246
rated pressureMpa0.7/1.00.7/1.00.7/1.25/1.61.25/1.6
rated steam temeperature170/184170/184184/193/204193/204
feed water temperature202020105
radiation area4.216.4310.5516.95
convection area20.6839.2390.45134.87
economizer area9.6616.5616.5653.13
valid grate area1.8523.155.188.395
applicable fuel*COALCOALCOALCOAL
exhaust gas temperature152/160152/161163/163.8/169.5163/169
design efficiency%77.73/77.2478.53/78.1879.37/79.30/78.9679.83/79.19
fuel consumptionkg/h170.74/172.93341.71/343.63673.22/676.27/682.11866.39/877.51
max part size for deliverymm5488*2254*27825694*2704*33246743*2954*35088244*2951*3704

TWO PART ASSEMBLED BOILER
boiler modelUnitSZL6-1.25/1.6-AIISZL8-1.25/1.6-AIISZL10-1.25/1.6-AIISZL12-1.25/1.6-AIISZL15-1.25/1.6-AIISZL20-1.25/1.6-AIISZL25-1.25/1.6-AII
capacityton/h681012152025
rated pressureMpa12.5/1.61.25/1.61.25/1.61.25/1.61.25/1.61.25/1.61.25/1.6
rated steam temeperature193/204193/204193/204193/204193/204193/204193/204
feed water temperature105105105105105105105
radiation aream218.1922.1425.825.834.11753.7899.21
convection aream2121.9158.86200.38250.17331.616411.8457.78
economizer aream253.13104.64130.8174.4/261.1117.72/117.2212.4476.16
valid grate aream27.559.3410.9812.7816.2420.8424.76
applicable fuelCOALCOALCOALCOALCOALCOALCOAL
exhaust gas temperature165.78/169.85161/165160/162158/150156.7/159.4153/159152/156
design efficiency%80.11/79.4479.95/79.9880.55/80.2880.68/80.7280.48/80.5681.09/80.7781.38/81.26
fuel consumptionkg/h863.28/874.781153.42/1161.381430.96/1442.741714.5/1721.82167.89/2164.72868.63/2884.73551/3556
max part size for deliverymm7100*2800*3500
7300*2540*2330
7300*3000*3500
7400*2700*2330
7600*3200*3500
7700*2900*2330
7600*3200*3500
8500*2900*2330
7350*3373*3505
8904*3370*1100
7814.7*3573*3511
9439*3768*1100
8478*2600*2740
Bulk packing
China 6 Ton Coal Fired Central Heating Boilers ASME Water Tube Package Boiler supplier

6 Ton Coal Fired Central Heating Boilers ASME Water Tube Package Boiler