Add to Cart
High-performance durable industrial wdr series electric steam
boiler with factory price
Safety performance of electric hot water boiler:
1. The electric heating pressurized hot water boiler produced by
the company is equipped with built-in steam separator in the
furnace, which solves the problem of excessive moisture content in
steam and ensures the stability and quality of steam.
2. boiler product design installed with a safety valve, even in the
case of the control system is not flexible, once the pressure
exceeds the set pressure, the safety valve will automatically open,
to prevent the boiler due to pressure instability and accidents.
3. electric heating pressure hot water boiler with low water level
protection function.
When the water supply is insufficient and the boiler is set to
stop, the boiler will automatically stop working to prevent the
boiler from damaging the electric heating elements and even burning
out due to dry burning.
4. boiler installed leakage protector.
Once the boiler due to improper operation of the circuit short
circuit, leakage of electricity, the boiler will automatically cut
off the circuit, timely protection of the furnace body from damage.
Advantages
1. An Electric Heating Steam Boiler is a pressure vessel device
that converts electrical into heat and then heat the water to
produce steam.
2. The piezoelectric furnace with a water storage capacity of 30L
or more at the highest safe water level is an electric heating
boiler;
3. The Electric Heating Steam Boiler adopts Japan Fuji temperature
control instrument, using PID self-tuning intelligent temperature
control technology, the control precision can reach the temperature
of about ±1 °C, and accurately control the temperature range used;
4. The heating main power supply uses solid-state module
non-contact switch circuit, adapt to frequent switching, and no
interference to the power supply network. And has anti-dry burning.
5. Electric Heating Steam Boiler Can be designed according to user
requirements to add hot oil cooling system to meet the production
process requirements of rapid cooling after heating;
6. To achieve centralized control of the boiler.
According to this automated system, the automatic timing switching
of the boiler in the boiler room is realized, thereby realizing the
circulating operation of the gas boiler, which not only can realize
the energy saving of the boiler heating, but also can effectively
extend the service life of the boiler.
Electric Heating Steam Boiler data sheet as follow (for reference
only) :
WDR Series Electric Heating Steam Boiler - Technical Parameter | ||||||||
Model | WDR0.75-1.0 | WDR1-1.0 | WDR1.5-1.0 | WDR2-1.0 | WDR3-1.0 | WDR4-1.25 | ||
Project | unit | |||||||
Rated evaporation | t/h | 0.75 | 1 | 1.5 | 2 | 3 | 4 | |
Fixed work stress | MPa | 1 | 1 | 1 | 1 | 1 | 1.25 | |
Saturated vapor temperature | °C | 184 | 184 | 184 | 184 | 184 | 193 | |
input power | KW | 540 | 720 | 1080 | 1440 | 2160 | 2880 | |
Input Current | A | 810 | 1080 | 1620 | 2160 | 3240 | 4320 | |
Rated voltage | V | 380 | ||||||
Power × number of groups | KW×P | 36×15 | 36×20 | 36×30 | 36×40 | 36×60 | 36×80 | |
a main steam valve caliber | DN | 40 | 40 | 65 | 65 | 80 | 100 | |
b safety valve caliber | DN | 2×40 | 2×40 | 2×40 | 2×40 | 2×40 | 2×40 | |
c inlet diameter | DN | 40 | 40 | 40 | 40 | 40 | 40 | |
d drain valve caliber | DN | 40 | 40 | 40 | 40 | 40 | 40 | |
Boiler dimensions | L | Mm | 2800 | 2950 | 3450 | 3500 | 3950 | 4100 |
L1 | Mm | 2400 | 2500 | 3050 | 2880 | 3200 | 3550 | |
W | Mm | 1800 | 1900 | 2180 | 2000 | 2100 | 2480 | |
W1 | Mm | 1550 | 1600 | 1430 | 1880 | 1980 | 2120 | |
H | Mm | 1550 | 1600 | 2100 | 2500 | 2650 | 2980 | |
H1 | Mm | 1300 | 1350 | 1850 | 1900 | 2100 | 2200 | |
Control cabinet size | A long | Mm | 1200 | 1200 | 1500 | 1500 | 1800 | 2100 |
B wide | Mm | 500 | 600 | 600 | 600 | 600 | 600 | |
C high | Mm | 1800 | 800 | 2000 | 2000 | 2200 | 2200 | |
weight | Kg | 2300 | 2850 | 3220 | 3550 | 4100 | 5200 |
Electric Heating Steam Boiler in factory work shop :