Add to Cart
12V/24V DC input dimmable motion sensor, integrated RF wireless, tunable white, tri-level dimming and remote control
Quick Detail:
1. Dual-processor technology, real Lux-off & daylight monitoring function for built-in application
2. RF wireless cluster control. ideal for retrofit project/ parking garage / staircase / corridor applications, easy installation, free of wiring
3. Two channels output, achieve color temperature adjustment and tri-level dimming
Size: 86*33*15.6mm
Features:
1. | Input current: | ≥50mA |
2. | Operation temperature: | -20℃~+70℃ |
3. | Detection range | up to 12m in diameter |
4. | IR | remote commissioning |
5. | Mounting height: | 3〜6m |
6. | RoHS compliant | |
7. | IP rating: | IP20 |
Source current / Sink current: Max. 20mA; 0-10V leads can not be short-circuit.
Features:
Low power consumption, power-saving.
Detect distance, ambient light and time-delay are adjustable, you
can make your own setting.
Microwave Radar Sensor, 360° wide angle detection and further
detection distance, can penetrate glass and veneer, but not wall.
Pluggable type of the terminals which make easier and much
convenient to install.
Applicable to monitoring equipment, warning facility, LED lamp,
fluorescent lamp, incandescent lamp, ventilator and magnetic valve
and so on.
Well suited to circulation areas, integral garages, store rooms,
toilets, kitchens, common stairs wells or corridors where there are
frequently people passing in an out of an area and the lighting
often gets left on accidentally.
Can be installed on wall, ceiling and anywhere of your house.
Remote control setting:
OCC OFF
Press “OCC OFF” button, the motion sensor will be disabled.
press “OCC ON” , “Reset” or “Ambient” to re-activate the motion sensor.
Dim
Press “Dim” button to automatically dim up or down the light
brighness during hold-time from 10% to 100%.
Another press to lock it down whendesired brightness is achieved.
OCC ON
Press “OCC ON” button, the sensor starts to work and all settings
remain the same as the latest status before the light was switched
on / off.
Reset function
Press “Reset” button, all sensor settings go back to factory
default settings.
Ambient learn
Press the button, the latest surrounding lux value overwrites
previous lux value learned, and set as the daylight threshold. This
feature enables the fixture to function well in any real
application circumstance.
Test mode
“Test mode”is for testing purpose only, for users to check the
functionality and choose the desired detection range. The sensor
goes to test mode automatically after pressing this button.
Users can quit this mode by pressing “ON/OFF”, “Reset”, or any
button of “Hold time”. The sensor settings are changed accordingly
.
Fast RF Grouping ( via DIP switch)
By simply selecting the same channel on each sensor unit, the
grouping is quickly and automatically completed. Totally
7 channels are available for fast grouping.
Channel OFF - OFF - OFF is not for fast grouping, it is for remote
control grouping only.