Environmental Heat Pump Heating And Cooling System With Copeland Compressor

Brand Name:Yushen
Certification:CCC, ISO, CQC
Model Number:SDNA-075Y
Minimum Order Quantity:1 set
Delivery Time:1-2weeks
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Foreign sales office: 588 South Qilianshan Road ,Putuo area, Shanghai,China
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

Environmental Heat Pump Heating And Cooling System With Copeland Compressor


Heat Pump Heating And Cooling System Advantages

  • With "Jet booster " Copeland compressor.work well in extreme envirronment -25C to +45C
  • Mutiple throttle channel, more acurate control of refrigerant quanity, saving operation cost
  • Yushen air-source Cooling equipment is 40% energy-saving than that of AC unit in general .
  • Industrial leading shell and tube heat exchanger in the water side
  • V shape big surface Al fins in air side, 3.1mm big fin space , reduce defrosting time.
  • Intelliegent defrosting , calculated automatically.

Heat Pump Heating And Cooling System Parameters


ModelSDNA-075Y Heat Pump Heating And Cooling System code name.pdf
Compressor capacity25HP
FunctionHeat
Electricity380V 3N-50Hz
Working conditions-25~+45
DataHeataNominal capacityKW44.5
Input powerKW18.3
COP/2.4
Heating IPLV(H)2.7
A7W35cKW/COP75.0/4.2
A2W35KW/COP62.5/3.20
A-7W35KW/COP52.5/3.0
A-15W55KW/COP45.5 /1.97
A-20W45KW/COP37.4/2.04
Max. running currencyA56
Compressor quantityset2
Refrigerant/charging quantity kg/R22/10*2
Air blow type/Top
Water pipe diametermm50
Rating flowm³/h12.6
Water side pressure losskPa≤45
Noise leveldB(A)62
Overall dimensions(L×W×H)mm2100×1100×2080
Weightkg730

a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity

A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃


Brief Introduction


Location: Jinan , Shandong province

Building area: 67000M2

System design: ultra low temperature air source heat pump+floor heating coil+ contral system

Quantity of air-source heat pump: 41 set


Project Overview:
The project is located in Jiangjun Road, Licheng District, Jinan City, Shandong Province, with a construction area of approximately 67,000 m2, apratment buildings are energy-saving buildings. The project is a residential renovation project, and the heat station is added later. It was successfully built before the heating season in 2014. Up to now, the whole heat station has been running well and stable. The average room temperature has reached 23°C or above. The average power consumption per unit area in the heating season is about 25 kwh. According to the calculation of the raw coal that is generally used by users, the annual coal savings can be about 1,168 tons.
The air source heat pump heating system could reduces SO2 by about 20 tons, reduces CO2 by about 2,100 tons, and reduces coal ash and slag emissions by about 350 tons per year.
China Environmental Heat Pump Heating And Cooling System With Copeland Compressor supplier

Environmental Heat Pump Heating And Cooling System With Copeland Compressor

Inquiry Cart 0