R404a Heat Pump Radiators With Tank Automatic Control Easy Operation

Brand Name:Yushen
Certification:CCC, ISO, CQC
Model Number:SLNA(B)-009U(P)
Minimum Order Quantity:1 set
Delivery Time:1-2weeks
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Foreign sales office: 588 South Qilianshan Road ,Putuo area, Shanghai,China
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

R404a Air Cooled Heat Pump With Tank and Water Pump for Radiator System


Brief Introduction

Air cooled ari source heat pump is an air conditioning equipment which delivery the energy in outdoor air into indoor.

It has functions of both heating and cooling.

The heat exchanger in air side is air cooled fin and tube exchanger; in water side is plate heat exchange or high efficient tank.

The indoor device could be radiator, underfloor coil or coil fans.

It use high efficient environmental friendly refriegrant Freon R404a

In winter, it produce 50C hot water; in summer, it produce 7C cool water.


Features

  • Modular design: it could connect with several machine according to project size
  • high efficient and energy saving: Up to 50% energy saving than other heating methods
  • low noise: 59DBA low noise design, give you a quite environment
  • easy operation
  • safe running: the medium inside system is water, no risk at all.

Model data/ Parameter


ModelSLNA(B)-009U(P)code name.pdf
Compressor capacity3HP
FunctionHeating and Cooling
Electricity220V-1N-50Hz
Working conditions-25~~+45
DataHeataNominal capacityKW5.8
Input powerKW2.52
COP/2.3
Heating IPLV(H)2.53
CoolbNominal capacityKW6.5
Input powerKW2.6
COP/2.5
Cooling IPLV(C)2.7
A7W35cKW/COP9.2/4.10
A2W35KW/COP8.0/3.6
A-7W35KW/COP5.9/2.7
A-15W55KW/COP5.0/1.90
A-20W45KW/COP4.5/1.95
Max. running currencyA18
Compressor quantityset1
Refrigerant/charging quantity kg/R404A/2.2
Air blow type/Side
Water pipe diameterinchG1〞
Rating flowm³/h1.6
Water side pressure losskPa≤35
Noise leveldB(A)59
Overall dimensions(L×W×H)mm1087×435×901
Weightkg70

a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal

b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity

c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃


China R404a Heat Pump Radiators With Tank Automatic Control Easy Operation supplier

R404a Heat Pump Radiators With Tank Automatic Control Easy Operation