Add to Cart
Electrical Safety Cone Calorimeter , Heat Release Test Heat Measuring Laboratories Support
Standard&Application
ISO 5660——Heat release, smoke production and mass loss rate
ASTM E 1354——Standard Test Method for Heat and Visible Smoke
Release Rates for Materials and Products Using an Oxygen
Consumption Calorimeter
ASTM E 1474——Standard Test Method for Determining the Heat Release
Rate of Upholstered Furniture and Mattress Components or Composites
Using a Bench Scale Oxygen Consumption Calorimeter
ASTM E 1740——Standard Test Method for Determining the Heat Release
Rate and Other Fire-Test-Response Characteristics of Wall Covering
or Ceiling Covering Composites Using a Cone Calorimeter
ASTM F 1550——Standard Test Method for Determination of
Fire-Test-Response Characteristics of Components or Composites of
Mattresses or Furniture for Use in Correctional Facilities after
Exposure to Vandalism, by Employing a Bench Scale Oxygen
Consumption Calorimeter
ASTM D 5485——Standard Test Method for Determining the Corrosive
Effect of Combustion Products Using the Cone Corrosimeter
ASTM D 6113——Standard Test Method for Using a Cone Calorimeter to
Determine Fire-Test-Response Characteristics of Insulating
Materials Contained in Electrical or Optical Fiber Cables
NFPA 264——Standard Method Of Test For Heat And Visible Smoke
Release Rates For Materials And Products Using An Oxygen
Consumption Calorimeter
CAN ULC 135——Standard Method of Fire Test of Exterior Wall
Assemblies
BS476 Part 15——Fire tests on building materials and structures..
Part 15: Method for measuring the rate of heat release of products
EN 45545-2:2013——Fire test to railway component
Cone Calorimeter Tester of Model: 6810 Accord with standard:ISO 5660 /ASTM E 1354/GB T16172
Technology data:
1.) 19inch standard instrument frame,17inch touchable screen pc insert
2.) cone heater powering rating:5000w,heat output rate:0~100kw/m2
3.) in the range of 50*50mm in the center surface of expose test sample ,center irradiation error no more than +-2%;
4.) sample size:100mm*100mm*50mm
5.) weight range:0~2000g;precision:0.1g;
6.) ignition system with safe cut device high pressure spark generator ,automatic positioning
7.) clockwise magnetic oxygen analyzer ,adopt pressure change of clockwise magnetic to measure the
oxygen density
8.) density range:0-25%,T90<1.5S,zero drift:<0.5%month,measure data deviation<0.5%month,
9.) non-dispersion infrared co and co2 analyzer:co:0~1%;co2:0~10%;
Sample size | 100*100*50mm |
Weight range | 0-200g |
precision | 0.1g |
Density range | 0-25% |
T90 | <1.5S |
Zero drift | <0.5%month |
Measure data deviation | <0.5%month |