Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance
Description:
1:1 gear ratio, Internal irrigation system.
Air pressure:245-392kPa
Atomized water pressure:200kPa
Atomized air pressure:200kPa
Rotation Speed:14000-20000r/min
Push button type chuck
Bur applicable:Φ2.35mm , Φ1.60mm
Noise :≤70dB
dental low speed handpiece Specification
- E-type connector
- Precise technology, Steady, no vibration while revolving,
offering a steady operation.
- Suitable for any E-type handpiece accords with ISO standard
- 135°C Autoclavable, suitable for both steam and chemical
autoclave
Contra angle handpiece
- 1:1 ratio 40,000P.M.
- The shank of the instrument mounted therein is 2.35 mm
- Fastening of the instruments with a turning latch
- Autoclavable 135°C
- For any lab or E-type motors
Dental handpieces right use way:
1. The need to use a clean , dry , oil-free air compressors for
medical use ;
2. The air pressure between 2.3-2.8kgf / cm2;
3. Place the adapter with quick connector at the bottom of a
combination of dental handpieces , and confirm that the card lock
fixed ;
4. Press the pedal , handpiece operation and examine whether the
normal operation of the spray head . If everything is normal, you
can start using the handpiece.
After each patient use , maintenance should be done as follows
1. First remove the diamond burs , and clean up all the teeth on
dental handpieces precipitate ;
2. Use a metal needle to clean the spray holes and fumaroles ;
Note: The spray holes and diamond burs into 40 -degree angle ,
fumaroles and diamond burs to a 30 degree angle.
3. Place the clean lubricating oil is sprayed into the axial hole
1-2 seconds ( diamond burs is plugged holes ) ;
4. In the bottom of the handpiece were ( with / without quick
connector ) two kinds of styling , make the right amount of
lubricant is injected into the bottom ;
5. The handpiece with quick connector combination ( first determine
the water switch is turned off )
6. Replace the diamond burs , surrounded by white silk cloth
handpiece head ( make sure the needle does not touch the diamond
burs and white gauze , so as not to tie ) ;
7. pedal depressed for about 20 seconds , look at whether there is
in white gauze on any stain. If there are stains on the white gauze
, again, add oil , starting from item 4 continued routine
maintenance , know that white gauze until no stain ;
8. Finally, no more than 135 degrees Celsius temperature and high
pressure sterilization.
Maintenance:
1. Considering safety first, please be careful to use it with full
attention.
2. Be limited to dentists who held the dental treatment
qualifications.
3. Strictly forbid decomposition and reconstruction by
unauthorized.
4. Please run point testing on outside of patients oral beforehand.
If feel anomalies, please stop using immediately and contact with
our after-sales center.
5. When appears abnormal during using, please stop it immediately
and contact with our after-sales center.
6. It will cause a high noise using a center-vibration or bended
bur and a handpiece of which bearing has been worn, A long time in
this state will be harm to people’s hearing. Forbid using a
vibration or bended bur, if appear high noise, please replace the
shaft core early
7. Do not use a bending , cracking, deformation and unqualified
bur. If using it, may cause a snap, or a flying off to injury
accident during operation process.
8. Please ensure the bur chuck be clean. If with contaminant inside
of it, may causes bur clamping weaken or shaft core vibration.
9. Please run the bur under the provision rotation-speed by bur
manufacturers.
10. Do not crash, especially to avoid falling.
11. Please install a bur or a standard stick before using.
12. Aslo remember to install a bur or a standard stick when not in
using.
13. Please unload the bur and handpiece when the running stopped in
completely.