Add to Cart
Durable Slow Speed Air Turbine Dental Drill 40000RPM External Water Spray
Description:
Professionally used by dentists as oral operative surgery tools for
dental implant.
The product is available for dental motor implant system in
accordance with ISO standard only.
Button type chuck.
Internal and external irrigation system.
Provides sufficient force at low speedMax torque 55N.cm
Ergonomic comfort grip.
20:1 gear ratio.
Reasonable price and excellent performance.
This handpiece is compatible with all e-type motors.
dental low speed handpiece Specification
- E-type connector
- Precise technology, Steady, no vibration while revolving,
offering a steady operation.
- Suitable for any E-type handpiece accords with ISO standard
- 135°C Autoclavable, suitable for both steam and chemical
autoclave
Contra angle handpiece
- 1:1 ratio 40,000P.M.
- The shank of the instrument mounted therein is 2.35 mm
- Fastening of the instruments with a turning latch
- Autoclavable 135°C
- For any lab or E-type motors
Features
1. Torque push button high speed handpiece, clean
head,anti-retraction system
2. Working air pressure: 0.2~0.3Mpa
3. Water pressure:198Kpa
4. Single water spray
5. Speed: 380,000RPM
6. Bur applicable:Φ1.59~1.60mm
7. Noise: ≤68dB
8. Inner tube materials: Stainless steel
9. Catridge:Import opening type catridge
10. Connector: 4 holes/ 2 holes
Maintenance:
1. Considering safety first, please be careful to use it with full
attention.
2. Be limited to dentists who held the dental treatment
qualifications.
3. Strictly forbid decomposition and reconstruction by
unauthorized.
4. Please run point testing on outside of patients oral beforehand.
If feel anomalies, please stop using immediately and contact with
our after-sales center.
5. When appears abnormal during using, please stop it immediately
and contact with our after-sales center.
6. It will cause a high noise using a center-vibration or bended
bur and a handpiece of which bearing has been worn, A long time in
this state will be harm to people’s hearing. Forbid using a
vibration or bended bur, if appear high noise, please replace the
shaft core early
7. Do not use a bending , cracking, deformation and unqualified
bur. If using it, may cause a snap, or a flying off to injury
accident during operation process.
8. Please ensure the bur chuck be clean. If with contaminant inside
of it, may causes bur clamping weaken or shaft core vibration.
9. Please run the bur under the provision rotation-speed by bur
manufacturers.
10. Do not crash, especially to avoid falling.
11. Please install a bur or a standard stick before using.
12. Aslo remember to install a bur or a standard stick when not in
using.
13. Please unload the bur and handpiece when the running stopped in
completely.