ACSR Overhead Bare Conductor With Code Is 16~1120 Basic Design To BS 215-2 / BS EN 50182 / IEC 61089 (AAC, AAAC, ACSR)

Brand Name:Zhenglan cable
Certification:3C,ISO 9001:2015,ISO 14001:2005
Model Number:ACSR Overhead Bare Conductor
Minimum Order Quantity:100 meters
Delivery Time:15-30 days
Payment Terms:L/C, T/T,
Contact Now

Add to Cart

Active Member
Location: Zhengzhou Henan China
Address: Floor 49, South Tower of Greenland Center, East Zhengzhou district, Zhengzhou, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Overhead Bare Conductor Which The Code Is 16~1120 Basic Design To BS 215-2 / BS EN 50182 / IEC 61089 (AAC, AAAC, ACSR)


Overhead Bare Conductor APPLICATION:


Bare aluminum conductors, especially in the form of Aluminum Conductors Steel Reinforced (ACSR), have been widely used for Overhead Transmission Lines as the most cost-effective and dependable product.


As the name implies, ACSR is a concentrically stranded conductor composed of one or more layers of hard-drawn EC grade Aluminum Wires over a high strength coated steel core. The core may be single wire or stranded, depending on the size. Because of the numerous stranding combinations of aluminum and steel wires that may be used, it is possible to vary the portions of aluminum and steel so as to obtain the most suitable relation between current carrying capacity and mechanical strength for each application.


ACSR has long been widely used as overhead high-tension transmission lines and has an established reputation for economy and dependability.


Overhead Bare Conductor CONSTRUCTION

ACSR is concentrically stranded conductor with one or more layers of Aluminium wire hard-drawn 1350-H16

on the galvanized steel wire core. The core may be single wire or stranded depending on the size. Steel wire is available in Class A or B galvanization as corrosion protection.


ACSR is according to electrical and mechanical strength requirements of transmission or distribution cable, can provides an appropriate design combining the quantity of Aluminium and galvanized steel wires.


Overhead Bare Conductor STANDARD:

Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards


Overhead Bare Conductor CHARACTERISTICS:

1. Simple construction;

2. Easy installation and maintenance;

3. Lower price and large transmission capacity;

4. Better for long distance power transmission;


ELECTRICAL PROPERTIES:


Density@20℃Aluminium: 2.703 kg/dm
Galvanised Steel: 7.80 kg/dm
Temperature Coefficient@20°CAluminium: 0.00403 (°C)
Resistivity@20°CAluminium: 0.00403 (°C)
Linear ExpansivityAluminium: 23 x10 (°C)
Galvanised Steel: 11.5 x10 (1/°C)

Service Conditions

Ambient Temperature-5°C - 50°C
Wind Pressure80 – 130kg/m2
Seismic Acceleration0.12 - 0.05g
Isokeraunic Level10 – 18
Relative Humidity5 – 100%

CONSTRUCTION PARAMETERS:

IEC 61089


CODE


Nominal Area

Stranding OverallOverall Diameter

Weight

Breaking

Load

Electrical

Resistance

@20℃

Current

Rating*

ALSteelTotalALSteel
mm2mm2mm2No.xmmNo.xmmmmKg/KmKNΩ/KmA
16162.6718.76/1.841/1.845.5264.66.081.793485
25254.1729.26/2.301/2.306.9100.99.131.1478112
40406.6746.76/2.911/2.918.73161.514.40.7174150
636310.573.56/3.661/3.6610.98254.421.630.4555198
10010016.71176/4.611/4.6113.83403.834.330.2869263
1251256.9413218/2.971/2.9714.85397.929.170.2304299
12512520.414526/2.477/1.9215.64503.945.690.231302
1601608.8916918/3.361/3.3616.8509.336.180.18347
16016026.118626/2.807/2.1817.74644.957.690.1805351
20020011.121118/3.761/3.7618.8636.744.220.144398
20020032.623326/3.137/2.4319.81806.270.130.1444402
25025024.627522/3.807/2.1121.53880.668.720.1154458
25025040.729126/3.507/2.7222.161007.787.670.1155461
31531521.833745/2.997/1.9923.911039.679.030.0917526
31531551.336626/3.937/3.0524.871269.7106.830.0917530
40040027.742845/3.367/2.2426.881320.198.360.0722607
40040051.945254/3.077/3.0727.631510.3123.040.0723610
45045031.148145/3.577/2.3828.561485.2107.470.0642651
45045058.350854/3.267/3.2629.341699.1138.420.0643655
50050034.63545/3.767/2.5130.091650.2119.410.0578693
50050064.856554/3.437/3.4330.871887.9153.80.0578697
56056038.759945/3.987/2.6531.831848.2133.740.0516741
56056070.963154/3.8519/2.1832.682103.4172.590.0516745
63063043.667445/4.227/2.8133.752079.2150.450.0459794
63063079.871054/3.8519/2.3134.652366.3191.770.0459798
71071049.175945/4.487/2.9935.852343.2169.560.0407851
71071089.980054/4.0919/2.4536.792666.8216.120.0407856
80080034.683572/3.767/2.5137.612480.2167.410.0361910
80080066.786784/3.487/3.4838.282732.7205.330.0362912
80080010190154/4.3419/2.6139.093004.9243.520.0362916
90090038.993972/3.997/2.6639.92790.2188.330.0321972
9009007597584/3.697/3.6940.593074.2226.50.0322974
1000100043.2104372/4.217/2.8042.083100.3209.260.02891031
1120112047.3116772/4.4519/1.7844.53464.9234.530.02581096
1120112091.2121184/4.1219/2.4745.313811.5283.170.02581100

China ACSR Overhead Bare Conductor With Code Is 16~1120 Basic Design To BS 215-2 / BS EN 50182 / IEC 61089 (AAC, AAAC, ACSR) supplier

ACSR Overhead Bare Conductor With Code Is 16~1120 Basic Design To BS 215-2 / BS EN 50182 / IEC 61089 (AAC, AAAC, ACSR)

Inquiry Cart 0