450mm Diameter Bowl Middle Speed 2 Phase Solid Bowl Centrifuge
XBSY Centrifuge provides solutions to all technological problems of solids-liquid and liquid-liquid separation, specialized in industrial centrifugal separation markets. These solutions help customers to clarify, concentrate, and separate products in production.
Centrifuge Model LW450×1000-N for separation of detrital material of drilling muds is widely used in solid control system for drilling mud to separate the solids phase of mud, remove harmful fine drill solids such as debris, etc. in the mud fluid, or recover weighting materials such as barite etc. so as to reduce the cost of mud fluid.
Centrifuge Bowl and screw conveyor are made of stainless steel (No. 304/316) for high resistance to wearing and erosion.
Model LW450×1000-N centrifuges with line frequency control system are split into model N1, model N2 and model N3 based on the rated speed of the bowl, respectively representing the rated speed of 1800r/min, 2000r/min and 2200r/min. In addition, centrifuges with variable frequency control system are available. See Chapter 2 “Technical Parameters” for details.
Over 400 sets are widely used in overseas market including United
States, Russia, South America, Middle Asia and Middle East. With 7
patents given including a special controller for flow ajustment.,
Screw conveyor are bonded with hard alloy blocks that improves the
service life up to 5 years..
Max through capacity up to 80 m3/h (SG<1.1)
It is a large-displacement model with high rev. and large treatment
volume developed by us and a unique model among domestic petroleum
drilling fluid-purpose centrifuges.
Technical Parameters Table
Technical parameters | Unit | Rated freq. LW 450×1000-N | Variable freq. LW 450×1000BP-N | ||||
N1 | N2 | N3 | |||||
Inner diameter of bowl | mm | 450 | |||||
Active length of bowl | mm | 1000 | |||||
Max. rotation speed of bowl | r/min | 2500 | |||||
Active rotation speed of bowl | r/min | 1800 | 2000 | 2200 | ≤ 2200 | ||
G-force | 815 | 1007 | 1219 | ≤1219 | |||
Differential speed of conveyor | r/min | 17~36 | ≤44 | ||||
Rotation direction of the bowl and the pulley of the gearbox | To be clockwise when observed from the small end of bowl | ||||||
Characteristics of conveyor flight | Double-ended, left-rotated | ||||||
Max. throughput (specific gravity <1.1) | m3/h | 40 | 45~50 | 50~60 | |||
Main motor | Model | YB200L-4 | YB225S-4 | YB200L-4 | |||
Rated power | kW | 30 | 37 | 30 | |||
Rated speed | r/min | 1470 | 1480 | 1470 | |||
Back motor | Model | YB160M-6 | |||||
Rated power | kW | 7.5 | |||||
Rated speed | r/min | 970 | |||||
Model of feed pump | Centrifugal pump LSB23J or SB23J | ||||||
Overall dimension | length | mm | 2750 | ||||
width | 1580 | ||||||
height | 1720 | 1780 | 1720 | ||||
Overall weight (including feed pump) | kg | 3400 | 3500 | 4100 |
Circumstance Conditions:
Ambient temperature: -20°C~+50°C
Relative humidity of ambient air: ≤95%
Explosion protection mark : ExdⅡBT4
Corrosive environment: No active gas or steam that will destroy the
metal
Degree of electrical protection: IP54
SS High quality brand materials:
Rules of Safe Operation
A. Cranes and slings can not bear excessive load, regular check shall be given to the slings so as to ascertain whether they are in good state.
B. The sustained centers shall be checked before lifting to ensure that the strength of the sustained centers meet the requirement of hoisting.
C. Make sure the installation platform is firm enough to bear adequate weight.
A. All safety protection guards shall be installed before starting up.It is forbidden to open the guards to observe the running state of the machines.
B. During the operation of the centrifuge, touch to moving parts and rotation parts should be avoided.
C. It is forbidden to brake in any way before the equipment is stopped.
D. If there is abnormal noise and vibration, close down immediately and make troubleshooting.
E. It is forbidden to have the machine running at the rotating speed out of active speed that indicated in the instruction and nameplate.
A. It is not allowed to disassemble and adjust the centrifuge prior to cutting off the power and stopping the bowl.
B. When opening the cover of vessel, it should be opened sufficiently and be fixed to prevent the sudden closure of the cover and injure the operators.