Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight

Brand Name:TYHD
Certification:type test report
Model Number:TYHD-AI9
Minimum Order Quantity:1 set
Delivery Time:within 3-5 working days
Payment Terms:TT,LC,westunion
Contact Now

Add to Cart

Site Member
Location: Beijing Beijing China
Address: Room1301, Building 11, yard 88 , Sanluju Road, Fengtai District, Beijing, China
Supplier`s last login times: within 12 hours
Product Details Company Profile
Product Details

Safety criterion

Welcome to use remote transmission unit manufactured by us. Each remote terminal uint has already experienced the complete assembly, test and inspection, also the careful check and adjustment before delivery, which has been in good condition when transport.


Device description

Remote terminal uint is the data acquisition and communications forwarding device for power distribution network load monitoring, fault detection and positioning system, which can be set as the practical distribution terminal device of two remote (remote signaling, telemetry) functions in the distribution automation system via terminal parameter configuration, which can also be set as the traditional distribution terminal device of remote fault positioning system.

Remote terminal uint is to process and analyze the information from overhead indicator sent via wireless and then send the circuit load current and fault information to the main distribution network station via GSM short messages or GPRS communication.


Working principle

Remote terminal uint is to receive the circuit fault information and circuit load operation information from overhead indicator installed in the circuit via wireless for analysis and compiling and then sends the information to main distribution network station via GPRS/GSM communications, to realize the online monitoring, fault detection and positioning functions of distribution network.


GSM or GPRS forwarding

GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.


Remote upgrade

The equipment program can be upgraded conveniently through master remote maintenance station.

Work mode setting

The terminal can be in the two-remote or one-remote working mode by setting the intrinsic parameters of remote terminal uint.

Two-remote working mode: the terminal is online in real time, and the circuit load current and circuit status can be uploaded.

One-remote working mode: the terminal is online regularly; when the circuit breaks down, the terminal opens GPRS module power supply and sends the fault information to main distribution network station.

The equipment cover is opened

Technical parameters

Dimension of repeater stationH×W×T=388mm×366mm×368mm
Weight of repeater station6.75kg
Applied voltage grade7~69kV overhead line
Circuit load current0~630A
Rated working voltage5.5V-7.5V
Overall power consumption<0.4W
Work time in rainy weather≥10 days
Solar panelOrganic glass protection, amorphous silicon, and 30 years of service life
Power of solar panel12W/10V
Quantity of cooperation indicators12
GPRS moduleE-GSM/GPRS 900/1800 dual band
Working temperature range (lead-acid battery)-35℃~75℃
Working temperature range (lithium iron phosphate)-20℃~75℃
MTBF>5×104 h

Remote Transmission Unit


China Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight supplier

Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight