48Vdc input 2000Va 220Vac/50Hz Standalone Inverter


TBB TP600 series inverter could achieve a compact size of maximized power density. Here are the Features;


TP600-1U standalone inverter features an integrated utility bypass. With a dip switch, the inverter can be set into AC priority mode, of which power is always connected to the AC utility line and will switch to inverter power line when AC utility fails with transfer time less than 8ms.


The performance of TP600-1U of inverter is at top of the market with peak efficiency up to 90% and small harmonics on DC side and it can be interfaced with RS232 and RS485.

  • Standalone design
  • Working mode selectable (AC priority or DC priority) with 5-8ms transfer time
  • Pure sine wave, THD<3%
  • High Frequency design
  • DC/AC isolation improving system security
  • Available with DC input 24VDC, 48VDC,110VDC or 220VDC
  • Voltage and Frequency adjustable by distributor within the specific range.
  • Thermal controlled fan speed
  • Max efficiency 90%
  • User’s friendly LED display
  • Complete protections with auto recovery
  • Input reverse polarity protection
  • RS232+RS485 and Dry point
  • EMI/EMC

Structure



Specifications

TP600M and TP600S (24VDC/48VDC models)

ModelTP610 / TP620 / TP630TP640 / TP650 / TP660
Electrical
DC input24Vdc or 48Vdc48Vdc
Dc input range.-17% ~ +25%
AC Input
AC input230Vac or 110Vac (-25%~+20%)230Vac (-25%~+20%)
Frequency range±10%
Output power1kva, 2kva, 3kva4kva, 5kva, 6kva
Wave formPure sine wave
Power factor0.8 *0.7
Nominal output voltage230Vac or 110Vac230Vac
Voltage variationMax ± 2%
Output frequency50/60Hz ± 0.1Hz
EfficiencyMax 88%
THD<3% liner load
<5% non-liner load
Crest factor.3:1
Overload125% 10secs
110% 10mins
Transfer time5-8ms
Dynamic response time< 30ms
LVD20Vdc or 40Vdc40Vdc
Display & Communication
Communication InterfaceRS232 and RS485
4xDry contact
Safety & Environment
Operating Temp.Full load, <-20℃> - 40℃
Derating using, 40℃ - 60℃
Isolation1500Vrms
Mechanical
Dimension (WxH)19"2U
Depth256mm / 321mm / 390mm321mm / 390mm
Weight6kgs / 12kgs /15kgs12kgs / 15kgs
Coolingforced fan with thermal control
EnclosureIP20
Standard
LVDEN60950-1
EMCEN55022
  1. The output power factor for TP630M is 0.7
  2. Overload capability of TP660S is different, please consult us.
    STS
    Input
    Voltage range:-25% - +20%
    Frequency range: ±10%
    Output
    Work modeAC priority or inverter priority
    Transfer time4ms
    Rated powerVarious