NACA.XXXQ4-S6 / SP1VA Current Transducers


Product Details

product manual

NACA XXXQ4-S6/SP1VA series triple current sensor is suitable for accurate measurement of AC, DC and pulse current isolation. The primary side and the secondary side are completely insulated during measurement.


Product Info


Performance requirements

parameter name

symbol

unit

parameter

condition

Minimum

Typical value

Max

Electrical parameters

Maximum range

IP

A

800A~1200A

For more details, please contact CRRC

Storage temperature

TS

°C

-40


125


voltage

UC

V

4.75

5

5.25


Output voltage (linear)

Vout

V

Vout=(Uc/5)·(V0+G·Ip)

@UC

Sensitivity

G

mV/A

2000/Ip

@UC=5V

Zero output

VO

V


2.5


@UC=5V

Current consumption

IC

mA


39

45

@ UC=5V,No load on Vout

Load Resistance

RL

4.7

10



Load capacitance

CL

nF



5


Output internal resistance

ROUT

Ω

2

4

8

DC

Performance parameter

Zero output error

X0

%

-0.5


0.5

@TA=25℃,@UC=5V

-0.75


0.75

@-40℃<TA<125℃,@UC=5V

Sensitivity error

εG

%


±1


@TA=25℃,@UC=5V


±2


@-40℃<TA<125℃,@UC=5V

Electrical zero offset

FLY

mV


±4



Magnetic zero offset

FROM

mV


±3



Proportional error

.R

%


0.5



Linearity error

εL

%

-1


1

of full range

Response time

tr

μs


2



bandwidth

BW

kHz

40



@ -3dB

Phase difference

∆φ

°

-4



@DC to 1kHz


Procurement information


1. Products can be customized according to your needs. You are welcome to provide physical samples or detailed process drawings to design, produce and process. 2. If there is no special requirement, our company will assign logistics distribution by default and deliver the goods to the customer factory.


3. Payment method: delivery after payment, which can be negotiated according to the specific order quantity.


4. The response time of the number of customers should not exceed 8 working hours.


5. Emergency on-site service time shall not exceed 24 hours.


6. Provide emergency support for customer's urgent shortage of spare parts.


China 4.75V 5V 5.25V 1200A AC Current Sensor for accurate measurement supplier

4.75V 5V 5.25V 1200A AC Current Sensor for accurate measurement

Inquiry Cart 0