Ac Dc Voltage And Current Transducer Closed Loop Hall Effect Current Sensor


TBV10/20X series voltage sensor is a closed loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit, it can measure DC, AC and pulse voltage.


Electrical data(Ta=25℃±5℃)

Type


Parameter

TBV10/20X

Unit

Rated input(Ipn)10mA
Measuringrange(Ip)20mA

Primary coil resister
200Ω

Secondary coil resister
100Ω
Turns ratio(Np/Ns)2000:1000T

Measure resister
±15V @±5mA 300(min) 750(max)Ω
±15V @±10mA 150(min) 500(max)
Rated output (Isn)@ Ip=±Ipn ±20±0.5%mA

Supply voltage
±15±5%V

Zero offset current
@ Ip=0 ≤±0.2mA

Offset current drift
@ -40℃~+85℃ ±0.6mA

Response time
@ Ip=Ipn ≤40µs
Linearity@ Ip=0-±Ipn ≤0.1%FS

Galvanic isolation
@ 50HZ,AC,1min 2.5KV

Applications

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical


Mechanical dimension(for reference only)


Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm


Directions for use

The accuracy of sensor will be the best when the current passes through resister R1 and becomes the rated primary current, and therefore the current to be measured by sensor should comply with the primary current 10mA.

For example: VIN=250V:

(precision )=±1.0%ofVIN(@Ta=+25℃),R1=25KΩ/ 10W,IP = 10mA


Considering resistance of primary coil (compared with R1 and temperature difference kept as low as possible) and electrical isolation within measure range (recommended), this sensor is suitable for measuring voltage.


Standards


  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date

ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to +125ºCTS
Mass (approx)6gM

Characteristics chart