PCB Mounting Closed Loop Hall Effect Sensor AC Current Transducer

Brand Name:TOKEN
Certification:CE;ROHS
Model Number:TBC-TBH
Minimum Order Quantity:10pcs
Place of Origin:CHINA
Price:Price Reconsideration
Contact Now

Add to Cart

Active Member
Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

PCB Mounting Closed Loop Hall Effect Sensor AC Current Transducer


The TBC-TBH Series current sensor is a closed loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit, the size of primary doesn’t affect test precision, no matter the location of primary in the hole of current sensor, It can really measure resolution 1000:1 and it uses for precision measurement of DC, AC and pulse current.


Electrical data(Ta=25℃±5℃)

Type

Parameter
TBC300TBHTBC400TBHTBC500TBHUnit

Rated input (Ipn)
12-30016-40020-500A

Measure range(Ip)
900(±24V,33Ω)1200(±24V,24Ω)1500(±24V,12Ω)A


Measure resister

with ±15V

@±300Amax 100(max)@±400Amax 82(max)@±500Amax 75(max)Ω
@±600Amax 27(max)@±800Amax 15(max)@±1000Amax 8.2(max)Ω


Measure resister

with ±18V

@±300Amax 120(max)@±400Amax 110(max)@±500Amax 100(max)Ω
@±900Amax 10(max)@±1200Amax 5.0(max)@±1200Amax 8.2(max)Ω
Turns ratio(Np/Ns)1:30001:40001:5000
Secondary coil resister405060Ω
Rated output (Isn)@Ip=±Ipn ±100±0.2%FSmA
Supply voltage±15~±24V
Power consumption20+IpX(Np/Ns)mA
Zero offset current@Ip=0 ≤±0.2mA
Offset current drift@ -40℃~85℃ ≤±0.5mA
Response time@100A/μS,10%-90% <1μs
Linearity@Ip=0-±Ipn ≤0.1%FS
Galvanic isolation@ 50HZ,AC,1min 6KV

di/dt accurately followed

>100A/μs
Bandwidth@ -3dB DC…100KHz

Applications

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical


Mechanical dimension(for reference only)

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm


Directions for use

Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.

The primary conductor should be≤120℃.

The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.


Standards


  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001

  • EN50178:1998
  • SJ 20790-2000

General date

ValueUnitSymbol
Operating temperature-40 to +85ºCTA