High Precision Hall Dc Current Sensor Closed Loop Hall Effect Sensor

Brand Name:TOKEN
Certification:CE;ROHS
Model Number:TBC-ES5
Minimum Order Quantity:10pcs
Place of Origin:CHINA
Price:Price Reconsideration
Contact Now

Add to Cart

Active Member
Address: NO.80,FEITIAN AVENUE,INDUSTRIAL CLUSTER LUKOU TOWN
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

High Precision Hall Dc Current Sensor Closed Loop Hall Effect Sensor


TBC-ES5 Series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit, the size of primary doesn’t affect test precision, no matter the location of primary in the hole of current sensor, It can really measure resolution 1000:1 and uses for precision measurement of DC, AC and pulse current.


Electrical data(Ta=25℃±5℃)

Type

Parameter
TBC10ES5TBC25ES5TBC50ES5TBC75ES5TBC100ES5

Unit


Rated input (Ipn)
±10±25±50±75±100A

Measure range(Ip)
±20±50±100±150±200A
Turns ratio(Np/Ns)1:1200±0.1%1:1200±0.1%1:1200±0.1%1:1500±0.1%1:2000±0.1%T

Inside measuring

resistance

30±0.1%12±0.1%6±0.1%5±0.1%5±0.1%Ω
Rated output@Ip=±Ipn ±1.0±0.2%V
Supply voltage+5±2.0%V
Power consumption20+IpX(Np/Ns)mA
Reference voltage+2.5±0.4%V
Zero voltage@Ip=0 +2.5±0.4%V
Offset voltage drift@ -40℃~105℃ ≤±0.05mV/℃

output drift
@ -40℃~105℃ ≤±0.05mV/℃
Linearity@Ip=0-±Ipn ≤0.1%FS
Bandwidth@ -3db 0~200KHz

Response time
@100A/μS,10%-90% ≤0.5µs

Galvanic isolation
@ 50HZ,AC,1min 3KV

Applications

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical


Mechanical dimension(for reference only)

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm


Directions for use

Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.

The primary conductor should be≤120℃.

The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.


The primary turns should be at the top of the sensor for the best magnetic coupling.

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

Custom design in the different rated input current and the output current available.


Standards


  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date

ValueUnitSymbol
Operating temperature-40 to +105ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)15gM

Characteristics chart

Pulse current signal response characteristic Effects of impulse noise

China High Precision Hall Dc Current Sensor Closed Loop Hall Effect Sensor supplier

High Precision Hall Dc Current Sensor Closed Loop Hall Effect Sensor

Inquiry Cart 0