TKC-BS/BR Open Loop Hall Effect Current Sensor Pulsed Currents Measurement


TKC-BS/BR series current sensor is a open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.


Electrical data (Ta=25℃±5℃,RL=2KΩ,CL=10000PF)


Type


Parameter

TKC50

BS/BR

TKC75

BS/BR

TKC100

BS/BR

TKC200

BS/BR

TKC300

BS/BR

TKC400

BS/BR

TKC500

BS/BR

TKC600

BS/BR


Unit


Rated input (Ipn)
±50±75±100±200±300±400±500±600A

Measure range(Ip)
±150±225±300±600±900±900±900±900A

Rated output
@Ip=±Ipn ±4±1%V

Supply voltage
±15 ±5%V

Power Consumption

+18,-10mA

Offset voltage
±25mV

Magnetic offset
±30±25mV

Offset drift
≤±1.5≤±1.0mV/℃

output drift
≤±1.5≤±1.0mV/℃

Linearity
@Ip=0-±Ipn ≤1%FS

Response time
@50A/μS, 10%-90% ≤3μS

Galvanic isolation
@ 50HZ,AC,1min 2.5KV

Wire length

650~750mm

Applications


AC variable speed drives

Static converters for DC motor drives

Variable speed drives

Power supplies for welding applications

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Switched Mode Power Supplies(SMPS)


Mechanical dimension(for reference only)


Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.


Directions for use


When the current will be measured goes through a sensor ,the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor).

Custom design in the different rated input current and the output voltage are available.


Standards


  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

General date


ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40 to +125ºCTS
Mass(approx)BS:65/BR:80gM

Characteristics chart


Pulse current signal response characteristic Effects of impulse noise


Input current-Output Voltage characteristic