275V / 385V 60kA - 120kA Type 1 Lightning Surge Protector For Electrical Panel

Brand Name:TSTLP
Certification:CE Compliance
Model Number:TS-385M60RM/4
Minimum Order Quantity:Negotiable
Delivery Time:Around 7 working days upon receipt of payment
Payment Terms:100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead
Contact Now

Add to Cart

Active Member
Location: Heyuan Guangdong China
Address: Hongdiyuan Industrial Park, Wufeng Avenue, Linjiang Town, Jiangdong New District, Heyuan, Guangdong, P.R.C.
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

40kA - 120kA Type 1 Surge Potector / Lightning Surge Protector for Electrical Panel / Distribution-room & Distribution-cabinet

(In(8/20) from 1kA - 200kA & Iimp (10/350) from 1kA ~ 50kA of Surge Protectors are available to manufacture with different housing & components per clients' request)


Type 1 Surge Protector is designed according to IEC 61643-11 & GB 18802.1 is for protect low voltage devices from surge damages, such as power distribution-room,distribution-cabinet and other important various power supply system.


  • Technical Data Part 1
Model Number

TS-385M60RM/4

TS-385M60/4

TS-275M60RM/4

TS-275M60/4

Rated voltage (max. continuous voltage)Uc385V~275V~
Nominal discharge current (8/20)In60 kA60 kA
Max. discharge current (8/20)Imax120 kA120 kA
Voltage protection levelUp≤ 2.5 kV≤ 2.2 kV

Technical Data Part 2

  • Main Character
  1. Lightning surge protector for electrical panel, distribution-cabinet... three-phase TN / TT systems
  2. Double terminals for parallet or series(V-shape) connection
  3. Pluggable module, easy for installation and maintenance
  4. High discharge capacity, quick response
  5. Low residual voltage, fine protection
  6. Multifunctional connection for conductor and busbars
  7. TS-385M60RM/4 lightning surge protector: Window will display red when fault occurs,remote alarm terminal at the same time
  8. TS-385M60RM/4 type 1 surge protector with both WINDOWS & LIGHTS indication),provide DOUBLE indications for users to check its working status : WINDOWS display GREEN and 3 Green lights will display HIGH GREEN when it’s working OK; When fault occurs, the windows display RED color and The green lights go off once the fuse upstream break.
  • Installation Instruction

According to lightning protection zones concept, for installation at LPZ 0A -1 or higher. This type 1 surge protector is usually installed in distribution-box or feeder bus of UPS, protecting devices or equipment downstream. Fuse must be installed at the upstream of the lightning surge protector or the lightning surge protector to make sure that the protected system has double protection. The value of the fuse used in a surge protector system should be conformed to:

  1. The value of FUSE should not be larger than the max withstand capacity of the SPD's backup fuse value.
  2. Under the status of the max. current in the power supply & close loop circuit available current, the fuse should be able to disconnect when overloaded or short-circuited.
  3. Take 1 & 2 into consideration, the fuse should be as large as possible to allow the maximum surge discharge of lightning surge protector.
  • Installation Diagram



PDF Catalog Download - TS-275M60-50-40RM T1 SPD.pd...


PDF Catalog Download - TS-385M60-50-40 T1 SPD.pdf


Tag: type 1 surge protector, lightning surge protector, surge protector for electrical panel

China 275V / 385V 60kA - 120kA Type 1 Lightning Surge Protector For Electrical Panel supplier

275V / 385V 60kA - 120kA Type 1 Lightning Surge Protector For Electrical Panel

Inquiry Cart 0