Green Power Deep Cycle Solar LiFePO4 Battery 12V 200Ah for RV Motorhome Caravan
Safety: LiFePO4 is the safest lithium-ion battery cathode material, not burining and explosion.
Long Cycle Life: Can charge and discharge more than 2000 times.
Environmental Protection: LiFePO4 does not contain any harmful heavy metal elements, pollution-free both in production and actual use.
SPECIFICATIONS
Nominal Voltage | 12.8V |
Nominal Capacity | 200Ah |
Limited Charge Voltage | 14.6V |
Discharge Cut-off Voltage | 10.8V |
Standard Charge Current | 40A |
Continuous Discharge Current | 100A |
Pulse Discharge Current (5s) | 250A |
Lifespan | > 2000 times |
Weight | 30Kg |
Dimension | 320*330*330mm |
Operation Temperature | _20~60℃ |
Storage Temperature | _20~70℃ |
APPLICATION FIELD
(1) Outdoor integrated iron battery power solution
The outdoor communication base station is directly exposed to the
sun. The life of the built-in lead-acid battery is usually less
than 2 years. This solution uses lithium iron phosphate battery,
which has excellent high temperature resistance and a life
expectancy of 5-10 years.
In this scheme, the battery has the advantages of small volume,
light weight, high temperature resistance and long service life,
and achieves the purpose of energy saving and emission reduction in
three aspects of “energy saving”, “material saving” and “land
saving”, and effectively reduces maintenance and operation costs.
(2) Non-air-conditioned base station power supply solutions such as
Murong
The base stations of the village-to-project are located in remote
rural areas. They are small in size and small in configuration.
Basically, there are no air conditioners, and power outages are
frequent. Lead-acid batteries have short life, frequent
replacement, and high maintenance costs in remote rural areas. The
use of iron batteries, high temperature performance, deep charge
and discharge, long cycle life, small size, light weight, light
installation, can achieve energy saving and emission reduction in
the three aspects of "energy saving", "land saving" and "material
saving". It also improves the quality of network power.
(3) Space-intensive indoor macro base station power solution
The number of indoor macro base stations is large, covering a large
area, requiring reliable power supply, so there are generally two
sets of battery backup power. The lead-acid battery in the station
has a large area and a heavy weight. When the traffic volume
increases and the capacity is increased, the space inside the
station restricts the possibility of adding new equipment.
If an integrated switching power supply is used with the iron
battery, the power supply and battery footprint in the equipment
room can be reduced to meet the needs of equipment expansion. At
the same time, the iron battery has excellent high temperature
resistance, and can increase the starting temperature of the air
conditioner in the station to about 35 degrees, which can reduce
the energy consumption of the air conditioner, effectively reduce
the operating cost by saving electricity costs, and achieve the
three aspects of “energy saving”, “land saving” and “material
saving”. The purpose of energy saving and emission reduction.
(4) Indoor coverage / distributed station power solution
The indoor coverage of the original 2G network, coupled with the
continuous construction of 3G and WLAN hotspots, will further
increase the number of indoor coverage stations. Since the indoor
coverage site is generally close to selecting the mains, the 48V
communication battery module or the iron battery UPS for power
supply can effectively solve such problems.
(5) High-voltage DC power supply system (HVDC) power supply scheme
for communication
For the power supply scheme of the data center, industry experts
proposed a 240V/336V high-voltage DC power supply system for
communication. The system's requirements for batteries are
characterized by high voltage (240V/336V), short time, and high
current discharge. If you use a rack-type lithium iron phosphate
battery pack, you have the following advantages:
(a) Light weight and save the cost of equipment room reinforcement;
(b) It is small in size and can be placed side by side with the
HVDC system in the form of a column head cabinet. It is not
necessary to establish a battery room separately, and the floor
space of the power supply system can be saved, and the installation
rate of the communication equipment rack can be improved;
(c) The iron battery can discharge at a high rate and reduce the
capacity of the battery configuration;
(d) The iron battery discharge platform is stable, and the stable
input voltage in the battery power supply mode prevents the device
from causing an abnormality due to a wide range of fluctuations in
the input voltage.
(6) Embedded UPS AC power system power supply scheme
For small and medium-sized data centers, developed countries in
Europe and America also have an embedded UPS distributed power
supply scheme, that is, using a small power UPS and a network
cabinet to supply power to the server in units of cabinets.
Choosing an iron battery UPS has the following advantages:
(a) Light weight and save the cost of equipment room reinforcement;
(b) Small size, 3KVA iron battery machine UPS only accounts for 2U
space of the network cabinet, increasing the server installation
rate;
(c) The long life of the battery, the mainframe and battery life
are almost the same, reducing the cost of battery replacement;
(d) Good safety, iron battery can not ignite or explode, meet the
high security requirements of IDC equipment room