KIC Thermal Profile With 7, 9 And 12-Channel Models Wireless Data Transfer With RF-Equipped Models

Brand Name:KIC
Model Number:X5
Minimum Order Quantity:1 pc
Delivery Time:3~5days
Payment Terms:T/T, Western Union
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 3rd Floor,Building A,Sha Tang Bei Fang Yong Fa Industrial Area,Sha Jing, Bao an, Shenzhen, China
Supplier`s last login times: within 24 hours
Product Details Company Profile
Product Details

7 Channels Standard Type K Thermocouple KIC X5 Thermal Profiler with USB Cable


Introduction
With 7, 9, and 12-channel models, the X5 is able to acquire a lot of data, allowing you to precisely evaluate each thermal profile and process in your factory. Measure slope, peak temperature, time above liquidous, and more. Data is transferred to your computer via a USB cable or, for RF models, wirelessly through radio frequency transmitters—no cable connection required.


KIC 'X5' Key Features
1, Robust hardware backed by 2-year warranty
2, Wireless data transfer with RF-equipped models
3, SPC (statistical process control) software included for documentation and production optimization
4, Simplifies oven setup: KIC’s optimization software selects the best oven setup for each new product in seconds
5, User-selectable setup criteria
6, Reduces profiling to a single number: The PWI (process window index) makes it easy for operators, techs, and engineers to see at a glance how close the profile comes to spec.
7, Immediate profile analysis: Objective and personnel-independent profile analysis gives you information you can bank on.


Specifications

ModelKIC X5
Dimension7-channel: 206 x 60 x 17 mm,with shield: 302 x 75 x 23 mm
9-channel: 206 x 75 x 17 mm,with shield: 312 x 90 x 23 mm
12-channel 206 x 98 x 17 mm,with shield: 323 x 113 x 23 mm
Accuracy± 0.5˚C
Resolution0.1˚C
Interal operating temp0˚C~85˚C
Sample rate0.1 to 10 readings/sec
Data points224,640
Data transferStandard model
USB 2.0 (Std-A/Mini-B) after datalogging run
RF model
Wireless over RF (radio frequency 433.92 MHz), sent real-time during datalogging run, or via USB 2.0 (Std-A/Mini-B) after datalogging run
Power3 AAA batteries, USB cable when connected to a computer
Thermocouple CapacityType K, standard (7, 9, or 12, depending on model)
Thermocouple Temperature Range-150˚C to 1050˚C
Thermal shieldCool Touch Stainless Steel 7 or 9 channel
Computer Configuration
Minimum System Requirements
Dual Core / 1 GHz processor PC w/2 GB RAM
2 GB available storage
Video 1024 x 768 resolution, 16-bit
1 available USB port for data download
1 available USB port for software key

China KIC Thermal Profile With 7, 9 And 12-Channel Models Wireless Data Transfer With RF-Equipped Models supplier

KIC Thermal Profile With 7, 9 And 12-Channel Models Wireless Data Transfer With RF-Equipped Models