Home /Batteries /

Smart Liquid Orifice Flow Meter With Pressure Transmitter

Smart Liquid Orifice Flow Meter With Pressure Transmitter

Brand Name:VACORDA
Certification:CE/TUV/ISO9001/SGS
Model Number:LG
Minimum Order Quantity:1 Piece/Pieces
Place of Origin:Sichuan, China (Mainland)
Supply Ability:100 Piece/Pieces per Month
Contact Now

Add to Cart

Active Member
Location: Zigong Sichuan China
Address: No. 41, Chengxi Rd, Yantan industrial zone, Yantan dist., Zigong city, Sichuan province, China
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Smart Liquid Orifice Flow Meter With Pressure Transmitter


Product Description

In the pipeline full with fluid, a throttling elements orifice plate is installed. When the fluid flows, static pressure difference occurs on both upstream and downstream sides. By using differential pressure transmitter or gauge, the differential pressure value is converted into standard current signal or aero-pneumatic signal to show the flow or volume of the fluid on the displaying instruments. orifice plate flow meter consists of the orifice plate pilot pressure piping and differential pressure gauge or transmitter.

(1)Nominal diameter:DN25-DN1000mm
(2)Accuracy:±1%FS
(3)Measuring Range:Standard 1:13 Extension 1:30
(4)Working pressure: 42.0MPa
(5)Medium temperature:-40°C- 450°C
(6)Medium viscosity: 30CP (heavy oil)
(7)Βvalue:0.2- 0.8
(8)Connection type:Flange or wafer type
(9)Flange standard:

DN600mm, PN2.0-PN26, HG20616; PN 32, HG20618

DN >600mm, PN2.0-PN15, HG20623 or customized

(10)Installation type:horizontal or vertical

Detailed Images

LG throttling gear is a primary device in a differential pressure flow measurement system, which consists of a throttle, a pressure-receiving device and a straight pipe section. Throttling device is divided into standard throttling device and non-standard throttling device, the one is coincident with IS05167 and GB/T2624 standard is the standard throttling device, the others are non-standard throttling deivce.
When the pipe filled fluid flows through the throttling device in the pipe, according to the law of conservation of energy and the equation of flow continuity, the stream will form a local contraction at the throttle, thereby increasing the flow rate, static pressure reduction, static pressure difference ΔP(or named differential pressure) before and after the throttle. The greater the flow rate of the fluid, the greater the differential pressure generated before and after the throttle, and the amount of fluid flow is measured by measuring the differential pressure before and after the throttle.
Standard throttling devices should normally be used whenever possible, and non-standard throttling devices can be used only when the fluid Reynolds number is small or contains impurities.
Technical Parameters
Nominal diameter:DN15~1200(More than 1200 negotiated orders)
Nominal pressure:≤42MPa
Inaccuracy:±0.5%~±1.5%
Installation method:Flange connection, Welded connection(or customized)
Pressure method: Corner connection pressure (ring chamber or separate drilling), Flange pressure, Span pressure or else
Straight pipe: Upstream5~10D,downstream2~5D

Throttling device classification
classificationPressure methodReference modelNominal diameter(mm)Nominal pressure(MPa)Diameter ratio
Orifice plateSmall orifice plateCorner connection pressureLG-XH-40/2515~401.0~420.1~0.7
Flange pressureLG-XF-40/2525~401.0~420.15~0.7
Standard orificeCorner connection pressureLG-BH-320/10050~4001.0~420.23~0.8
LG-BH-100/6550~2501.0~42
LG-BH-63/5015~1501.0~42
LG-BZ-16/600450~16000.6~2.5
LG-BZ-10/50450~10000.6~1.6
Flange pressureLG-BF-25/30050~7501.0~200.25~0.75
LG-BZ-40/15050~4001.0~20
Span pressureLG-BJ-63/15050~4001.0~63
Built-in orificeLG-BFC-260/8050~4001.0~42
Double orificeLG-SH-16/10025~4001.0~100.19~0.82
1/4 round orificeLG-HH-160/10025~4001.0~260.32~0.71
Conical inlet orifice plateLG-VH-16/10025~2001.0~4.00.12~0.32
Round hole plateLG-QH-6/100050~16000.25~2.50.32~0.71
LG-QH-25/60050~14000.25~2.5
NozzleSmall nozzleLG-MH-40/3225~401.0~260.3~0.71
Standard nozzleLG-PH-40/15050~6001.0~320.30~0.8
LG-PH-63/20050~6001.0~32
Long neck nozzleLG-CJ-260/8050~4001.0~320.22~0.8
Venturi tubeVenturi nozzleLG-LT-16/15065~4000.6~2.50.32~0.78
Classical venturiMachiningLG-WT-6/20050~6000.6~400.38~0.75
Rough weldingLG-WT-6/1200200~20000.6~2.50.38~0.73

Small orifice plate, Small nozzle Reference size table

Pressure LevelSizeDN15DN25DN32DN40
PN25D95115135145
L126128143149
PN40D95115135148
L126147148148
PN63D105135150165
L126152159177
PN100D95135150165
L126155162178

Note: The length L is based on the actual size, and the dimensions in the table are for reference only.

Company Profile and Certificate



China Smart Liquid Orifice Flow Meter With Pressure Transmitter supplier

Smart Liquid Orifice Flow Meter With Pressure Transmitter

Inquiry Cart 0