Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean Agent

Brand Name:Fireless
Certification:BSI/ILAC-MRA/CNAS/AL/MA
Model Number:Fireless 125
Minimum Order Quantity:1
Delivery Time:1-6weeks( depends on QTY,samples in stock)
Payment Terms:L/C, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Suzhou Jiangsu China
Address: Building C21, No.2588,WuzhongRoad,Wuzhong economic development zone,Suzhou City
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

Fixed Type Innovating Aerosol Extinguishing Systems Eco-friendly Clean Agent


Brief requirements of Aerosol Extinguishing Systems according to GA499.1-2010

  • Spray process and state-fire extinguishing device should be able to spray normally after switching on the start signal
  • During discharge, there shall be no open fire or spark at the nozzle, and no residue shall overflow during or after injection
  • After the completion of spraying, the shell shall not be deformed, burnt through or ignited on the surface of the shell.
  • The total filling mass of aerosol generator in a fire extinguishing device shall not be more than 10kg, and the deviation of filling mass shall not exceed 2% of its nominal mass.
  • The operating voltage of the electric initiator shall not be greater than 24 vd.c.
  • The raw materials used to produce aerosol generating agents should be non-toxic to organisms and the combustion products do not contain harmful ingredients that damage the atmospheric ozone layer.

Fireless 125 technical parameter:

ItemSpecification
Overall dimensions(mm)240( diameter)X126(height)
Extinguishing device weight(Kg)6.8
Agent quantity(Kg)3.5
Protected volume(m³)125
Working temperature(℃)-50℃~+95℃
Safety current(mA,DC)≤150mA
Discharge times)≤ 19
Service life(year)10

FAQ for technical terms

  • Do the protected area needed 100% closed?

Answer: no, it doesn’t .

  • what is ratio of open area to total area in enclosure?

Answer:Represents the unsealing degree of the enclosed space, and its value is the ratio of the unclosed open area in the enclosed space to the total surface area, expressed as a percentage.

  • What is flame extinguishing density?

Answer:The mass of an aerosol agent required to extinguish a fire in unit volume, g/m³.

  • What is discharge delay time?

Answer:The time when the fire extinguishing device receives the starting signal and the nozzle begins to spew hot gas sol extinguishing agent.

  • What is discharging time?

Answer:The time from the beginning discharging aerosol to discharging stopped.

  • What is outlet temperature in discharging?

Answer:During the process of discharge heat aerosol fire extinguishing agent, the outlet temperature is where 5 meters away from nozzle.

  • Is there any cooling equipment in the generator?

Answer:Yes, it’s medium or device installed in a fire extinguishing device to effectively reduce the temperature of a hot gas aerosol extinguishing agent before it passes through the nozzle.


Application:

data centers/ UPS/ ESP/ museums/ warehouses/ electric cabinets/ generator rooms panels/ engine rooms/ different transportation vehicles

China Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean Agent supplier

Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean Agent