Add to Cart
Portable Trace O2 Gas Analyzer
Technical Specifications
Performance | Operating Conditions | ||
Measurement Ranges | 0-10ppm,0-100ppm,0-1000ppm,0-1% | Operating Humidity | Less than 95%(Non-Condensing) |
Resolution | 0.01ppm | Operating Temp | 0℃ to +45 ℃ |
Response Time | <10s(100ppm-1%) | Inlet Gas Pressure | 0.5-30psig |
Repeatability | +/-0.5% FS | Flow Rate | <1 LPM |
Electrial Specifications | Mechanical Specifications | ||
Display | 3.5”LCD,320*240 Screen Resolution | Protection | Intnsically Safe,Class 1,Div 1 Group B,C,D |
Battery | Li-ion rechargeable,8 hours on full charge | Dimensions | Height:7.08” |
Input Charge Voltage | 115/230VAC | Weight | 2.85KG |
General Description
Design Simplicity & Ease of Use The POA 200 is designed for
ease of use, Incorporating all the features needed to make
installation and operation as simple as possible. Engineered with
leading industry experts, this instrument is fully configured and
calibrated that can be instantly incorporated into field service.
The on-site connections can be easily made with the supplied
Quick-Disconnect fittings, readily taking samples in your service
locations. An on-off by pass valve will make sure the sensor is in
an air tight chamber and stabilizing for the next measurement.
User Friendly Interface
Once powered on, the POA 200 will automatically adjust it’s charts
to the correct range of measurement switching between the different
ppm levels.
POA 200 is also fast to respond, ensuring that your process is
always monitored in real time. The POA 200 is calibrated traceable
to NIST standards at ten points over the range of 0.1ppm to 1% to
an accuracy of 0.1ppm concentration. The result gives a sensor that
is reliable for many years of operation.
Accurate & Responsive
The POA 200 incorporates a proprietary weak acidity electrochemical
sensor, tested and verified to ensure the instrument will provide
highly accurate and repeatable measurements even under miniscule
concentrations of Oxygen in the 0-10ppm range.
As the POA 200 measures the Oxygen concentration in the gas sample,
it will give a stable measurement in harsh conditions and is
generally unaffected by other gases. Flow rate is not critical to
measurement accuracy, though speed of response will be improved
with higher flow rate.
Rugged yet Lightweight
The POA 200 is constructed with 316 grade stainless steel. A
capative sealed, glaned cable connector offers IP68 protection from
any harsh environment.
At only 2.85kg, this portable analyzer can be comfortably carried
around via the supplied shoulder strap or the carrying case.
Powered by an internal battery, it provides the user with an
operation window of 16 hours continuously on full charge. Making it
ideal to make measurements in various locations.