AC 6KV DC 5KV Safety DC Ac Hipot Tester , Arc Detection Hipot Insulation Tester

Brand Name:Fanke High-voltage
Certification:ISO9001:2008
Model Number:9911/9912
Minimum Order Quantity:One unit
Delivery Time:1-2Weeks
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Wuhan Hubei China
Address: Layers Building 2,N0.2-2 Guannan Science&Technology Industrial Park, East Lake High-Tech Development Zone,Wuhan ,China
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

Portable Type AC Hipot Tester , AC 6KV DC 5KV Safety Tester , Programmable , Arc Detection
I. Product Description
The 9911/9912 Hipot tester is a high voltage and programmable safety tester with an output voltage of AC5kV and DC6KV. It can be widely used in the safety tests of household appliances, transformer, electrical equipments and components.

II. Refer Standard

  • EC60335-1, GB4706.1, UL60335-1 Safety of household and similar electrical appliances Part 1: General requirements
  • UL60950, GB4943, IEC60950 information technology equipment
  • UL60065, GB8898, IEC60065 audio, video and similar electronic equipment safety requirements
  • IEC61010-1, GB4793.1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements

III. Advantage

  1. AC/DC withstand voltage function
  2. Two arc detection methods are available: current mode, level mode
  3. Test results can be saved simultaneously
  4. With dual frequency integrated test, frequency range 50 Hz, 60 Hz
  5. Humanized operation interface
  6. English operation interface


IV. Technical Data and optional model

MODEL9911A9911B9912A9912B
ACOutput voltagerange0.050~5.000kV
accuracy±2% reading +5V
resolution1V
Max. Output capacity75W100W
Max. Rated current15mA20mA
Current gear2mA,15mA2mA,20mA
Lower limit current

(0~15.00)mA,
0=Do not judge the lower limit

(0~20.00)mA,
0=Do not judge the lower limit

Output waveformSine wave
Output waveform distortion≤ 2% (no load or pure resistive load)
Crest factor1.3~1.5
Output signal typeDDS+ amplifier
ACVoltage rise time

0.3s ~ 999.9s
0 = voltage rise time off

Test time

0.3s ~ 999.9s
0 = continuous test

Voltage drop time

0.3s ~ 999.9s
0 = voltage fall time off

Interval time

0.3s~999.9s
0=Interval time off


DC

Output
Voltage

range(0.050~6.000)kV(0.050~6.000)kV
accuracy±(2%reading+5V)±(2%reading+5V)
resolution1V1V
Max.output capacity30W60W
Max.rated current5.000mA9.999mA
Current gear2mA,5mA2mA,10mA
Current lower limit

(0~5.000)mA,
0=Do not judge the lower limit

(0~9.999)mA,
0=Do not judge the lower limit

Ripple coefficient≤5%, 6kV/5mA≤5%, 6kV/10mA
Discharge time≤200ms≤200ms
Max. Charging current5mA9.999mA
Voltage rise time

0.3~999.9s
0=voltage rise time off

0.3~999.9s
0=voltage rise time off

Test time

0.3~999.9s
0=Continuous test

0.3~999.9s
0=Continuous test

Voltage drop time0.3~999.9s 0=voltage drop time off0.3~999.9s 0=voltage drop time off
Interval time

0.3~999.9s
0=interval time off

0.3~999.9s
0=interval time off

Voltage
meter

range0.050kV~6.000kV
accuracy±(2%reading+5V)
resolution1V
Display valueRMS value

Current meter
Test rangeAC0 ~ 20mA
DC0 ~ 10mA
resolutionAC2mA gear:1uA, 20(15mA)mA gear,10uA
DC2mA gear :1uA, 10(5mA)mA gear,10uA
accuracy±(2%+5words)
Error Offset current0 ~ 2mA

Timer
range0.1s~999.9s
Accuracy/resolution±1%/0.1s


V.Supply list

  1. Host tester
  2. Power lead
  3. Test wire
  4. Manual and certificate



























China AC 6KV DC 5KV Safety DC  Ac Hipot Tester , Arc Detection Hipot Insulation Tester supplier

AC 6KV DC 5KV Safety DC Ac Hipot Tester , Arc Detection Hipot Insulation Tester

Inquiry Cart 0