12KV Transformer Capacitance & Tan Delta Test Set Automatic 0-12KV HV Output

Brand Name:Fanke High-Voltage
Certification:ISO9001
Model Number:FKGST 12KV
Minimum Order Quantity:One unit
Delivery Time:10 work days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Wuhan Hubei China
Address: Layers Building 2,N0.2-2 Guannan Science&Technology Industrial Park, East Lake High-Tech Development Zone,Wuhan ,China
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

12KV Transformer Capacitance & Tan Delta Tester , Automatic Tan Delta Tester , Generator Tan Delta Tester

I. Products Description

FKGST 12KV Tan Delta (dissipation factor) Tester consists of variable frequency power, tan delta bridge, testing transformer and standard capacitor inside the tester. Variable frequency power can produce five kinds of frequency: 45Hz, 50Hz, 55Hz, 60Hz and 65Hz under which test can be done. Variable frequency technique adopted in this tester can ensure high accuracy in high interference environment.

Model FKGST Automatic 12KV Capacitance &Dissipation Factor Test Set is used to measure dissipation factor (PF) in heavy interference site such as power plants or power substations. It can also be used in laboratory for high accurate test. The meter is whole in one designed: including precision digital bridge, power unit, reference capacitor (CN), step-up transformer and other electronic circuits. It’s also using frequency shift technology, FFT (Fast Fourier Transform algorithm) and digital filtering. When started, it’s running automatically and then outputs the results on LCD display and prints the results automatically.


II. Test principle

Fig 1 Wiring Diagram of Main Power
RX1---Sampling resistance in ungrounded test specimen measurement
RX2---Sampling resistance in grounded test specimen measurement
CN---Standard capacitor
RN---Sampling resistance of reference signal
CVT---Voltage output terminal in CVT measurement by means of self-excitation.

III. Technical Parameters
1. Input: 220V+5%, 50Hz, 1KVA
2. Output:voltage:0~12kV (0.5kV/step to raise voltage)

current:100mA continuous

Max. 200mA, 5min on/15min off (10kV)

Max.160mA, 5min on/15min off (12kV)

3.Test range:
3.1 voltage:0~12kV resolution:1V
3.2 capacitance: 10kV, 50pF~60000pF(50Hz)
12kV, 50pF~44000pF(50Hz)
0.5kV, 50pF~1uF(50Hz)
3.3 Max. resolution:0.01pF
3.4 Tan delta:0~10% Maximum resolution:0.00001

4.Accuracy:
4.1 voltage(RMS):+200V
4.2 capacitance:+(Reading*1.0%+1pF)
4.3 in ungrounded test specimen measurement +Reading*1.5%+1pF
4.4 in grounded test specimen measurement tan delta:+reading*1.0%+0.0005

5.Operational environment:
5.1operation temperature:-5℃~55℃
5.2 humidity:<85%
5.3 storage temperature:-20℃~55℃


III. Configuration:



SNNAMEQty
1FKGST Automatic 12KV Capacitance &Dissipation Factor Tester1set
210 meters Hipot measuring signal lines (red)1pec
310 meters measuring signal lines (black)2pecs
48 m CVT Low voltage output line1pec
5Power line1pec
68 m Earth line1pec
7Spare printing paper1pec
85A fuse1pec
9Feltpad1pec
10Manual1pec
11certificate of inspection1pec
12accessory case fro connection lines1pec
















China 12KV Transformer Capacitance &  Tan Delta Test Set Automatic 0-12KV HV Output supplier

12KV Transformer Capacitance & Tan Delta Test Set Automatic 0-12KV HV Output