Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance

Brand Name:Fanke High-Voltage
Certification:ISO9001
Model Number:FKGST
Minimum Order Quantity:One unit
Delivery Time:10 work days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Wuhan Hubei China
Address: Layers Building 2,N0.2-2 Guannan Science&Technology Industrial Park, East Lake High-Tech Development Zone,Wuhan ,China
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

Transformer Capacitance & Tan Delta Tester , Automatic Tan Delta Tester , Dielectric Loss & Capacitance​


I. Products Description


Model FKGST Automatic 10KV Capacitance &Dissipation Factor Test Set is used to measure dissipation factor (PF) in heavy interference site such as power plants or power substations. It can also be used in laboratory for high accurate test. The meter is whole in one designed: including precision digital bridge, power unit, reference capacitor (CN), step-up transformer and other electronic circuits. It’s also using frequency shift technology, FFT (Fast Fourier Transform algorithm) and digital filtering. When started, it’s running automatically and then outputs the results on LCD display and prints the results automatically.


FKGST Tan Delta (dissipation factor) Tester consists of variable frequency power, tan delta bridge, testing transformer and standard capacitor inside the tester. Variable frequency power can produce five kinds of frequency: 45Hz, 50Hz, 55Hz, 60Hz and 65Hz under which test can be done. Variable frequency technique adopted in this tester can ensure high accuracy in high interference environment.


II. Test principle

Fig 1 Wiring Diagram of Main Power

RX1---Sampling resistance in ungrounded test specimen measurement

RX2---Sampling resistance in grounded test specimen measurement

CN---Standard capacitor

RN---Sampling resistance of reference signal

CVT---Voltage output terminal in CVT measurement by means of self-excitation.


III. Technical Parameters

  1. Capacitance range: Internal HV: 3pF-60000pF/10kV; 60pF-1μF/0.5kV
  2. Test accuracy: Cx: ±(reading×1%+1pF)

    tgδ: ±(reading×1%+0.00040)

  3. External HV: 3pF-1.5μF/10kV; 60pF-30μF/0
  4. Resolution: Maximum 0.001pF, 4 valid figures.
  5. tgδ range:unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles.
  6. Test current range: 10μA-1A
  7. Internal HV: Set voltage range: 0.5-10kV
  8. Maximum output current: 200mA
  9. Buck-bust method: continuous stepless regulation
  10. Test frequency: 45, 50, 55 single frequency 45/55Hz automatic dual variable frequency
  11. External HV: In case of UST, maximum test current is 1A, and power frequency or variable frequency is 40-70Hz
  12. In case of GST, maximum test current is 10kV/1A, and power frequency or variable frequency is 40-70Hz
  13. CVT self-exciting low voltage output: Output voltage 3-50V, output current 3-30A
  14. Measuring duration: About 40s, depending on measuring method
  15. Input power supply: 180V-270VAC, 50Hz/60Hz±1%, supplied by alternating current or generator
  16. Computer interface: Standard RS232 interface
  17. Printer: WH-A7 mini-type thermal printer
  18. Environment temperature: -10-50
  19. Relative humidity: <90%
  20. Overall dimension:460×360×350mm
  21. Weight:28kg


III. Configuration:


SNNAMEQty
1FKGST Automatic 10KV Capacitance &Dissipation Factor Tester1set
210 meters Hipot measuring signal lines (red)1pec
310 meters measuring signal lines (black)2pecs
48 m CVT Low voltage output line1pec
5Power line1pec
68 m Earth line1pec
7Spare printing paper1pec
85A fuse1pec
9Feltpad1pec
10Manual1pec
11certificate of inspection1pec
12accessory case fro connection lines1pec

China Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance supplier

Transformer Capacitance & Tan Delta Test Equipment Dielectric Loss & Capacitance

Inquiry Cart 0