0.001mW DTA Glass Transition Temperature Testing Machine

Brand Name:BAXIT
Certification:CE
Model Number:BXT-DTA1250
Minimum Order Quantity:1
Delivery Time:3 working days
Payment Terms:L/C, T/T, D/A, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: No.5616th, Caoan Road, Jiading District, Shanghai
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

BAXIT DTA differential thermal analyzer


Overview:

Differential thermal analyzer is a technique to measure the temperature difference between a substance and a reference substance under a programmed temperature control. In the DTA test, the change of sample temperature is caused by the endothermic or exothermic effects of the phase transition or reaction.

Standard:

GB/T 19466.2-2004 / ISO 11357-2: 1999 Part 2: Determination of glass transition temperature;

GB/T 19466.3-2004 / ISO 11357-3: 1999 Part 3: Determination of melting and crystallization temperature and enthalpy;

GB/T 19466.6-2009/ISO 11357-3:1999 Part 6 Oxidation induction period Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT).

Technical characteristics:

1. Greatly improving the sensitivity and resolution as well as better baseline stability by new fully closed advanced ceramic furnace design structure.
2. High sensor sensitivity, i
mported alloy sensor, more corrosion resistance, oxidation resistance.
3. Cortex-m3 kernel ARM controller is used for faster computation and more accurate temperature control.
4. USB two-way communication is adopted to fully realize intelligent operation.
5. Use the 7-inch 24-bit color full-color LCD touch screen to display the status and data of the instrument in real time.
6. Software can realize a variety of data processing, such as calculation of enthalpy, glass transition temperature, oxidation induction period, melting point and crystallization of substances, and so on. Intelligent software design, automatic drawing of the instrument in the whole process,

Technical Parameters:

DTA range0 ~ 2000V
Temperature rangeRT ~ 1250 ° C
Heating rate0.1~80°C/min
Temperature resolution0.01 ° C
Temperature accuracy± 0.1 ° C
Temperature repeatability± 0.1 ° C
DTA accuracy0.01V
DTA resolution0.001mW
DTA sensitivity0.001mW
Temperature control modeHeating: Parameters can be adjusted according to the needs of the program control.
Constant temperature: the program controls the constant temperature time to set arbitrarily.
Curve scanheating scan
Atmosphere controlAutomatic instrument switching
Display mode24bit color, 7 inch LED touch screen display
Data interfaceUSB standard interface, supporting the corresponding operating software
Parameter standardEquipped with standard calibrator with one-button calibration function, users can calibrate the temperature by themselves
Working powerAC220V 50Hz/60Hz

Applications:

Measure the melting point, melting heat, crystallization and crystallization heat, phase change reaction heat, thermal stability (oxidation induction period), glass transition temperature, oxidation or reduction reaction, destruction of lattice structure and other chemical reactions. Mainly measure the physical and chemical changes related to heat.

Product Picture:



China 0.001mW DTA Glass Transition Temperature Testing Machine supplier

0.001mW DTA Glass Transition Temperature Testing Machine

Inquiry Cart 0