Oxygen Index Tester
First, the scope of application:
Suitable for the determination of the burning properties of
plastics, rubber, fiber, foam, film and film and textile materials
Second, the main technical parameters:
Flow meter display
2. Machine accuracy: 2.5
3. Flow adjustment range: 0-10L/min (60-600 L/h)
4. Oxygen input pressure: >0.25Mpa
5. Measurement range: 0 ~ 100% O2;
6. Combustion tube: inner diameter ≥75mm total 450mm
7. Gas flow rate in the combustion cylinder: 40mm ± 2mm / s
8. Pressure gauge accuracy 2.5
9. Flowmeter: 0-10L/min (60-600 L/h) adjustable
10. Test environment: temperature 10-35 ° C, humidity 45-75%
11. Input pressure: 0.2-0.3MPa
12. Working pressure: nitrogen 0.1-0.15Mpa oxygen 0.1-0.15Mpa
13. Oxygen/nitrogen mixed gas inlet: including regulator valve,
flow regulating valve, gas filter and mixing chamber
14. Sample holders can be used for soft and rigid plastics,
textiles, fire doors, etc.
15. Propane (butane) ignition system, flame length 5mm-60mm can be
adjusted freely
16. Gas: Industrial grade oxygen/nitrogen (user-supplied).
17. Igniter: It has a metal tube and a nozzle with an inner
diameter of Φ2±1mm at the end. It can be inserted into the
combustion cylinder to ignite the sample.
18. Self-supporting material sample holder: can be fixed at the
axial position of the combustion tube and can clamp the sample
vertically
19. Non-self-supporting material sample holder: all stainless
steel, can fix the two vertical sides of the sample on the frame at
the same time
Working conditions of HC-2 oxygen index meter
1. Ambient temperature: -10 ° C ~ 45 ° C
2. Relative humidity: <85%;
3 Use gas: GB3863 industrial gaseous oxygen; GB3864 industrial
gaseous nitrogen; both bottles of gas should be pressure regulating
valve;
5. Input pressure: 0.25-0.4Mpa;
6. Working pressure: 0.15Mpa;
Design standard: GB/T 2406-1993
Compliance with standards: ASTM D 2863, ISO 4589-2, NES 714 GB/T
5454 GB/T 10707 GB/T 8924-1988 GB/T 16581-1996 IEC 61144-1992
Fourth, product configuration
Host 1
2. Ignition 1
3. Glass tube 2
4. Glass beads 1 bag (into the combustion column)
5. Nylon tube Ф 4 1.2 m (connecting the combustion column to the
main unit)
6. Sealing ring Several (already placed on the Ф4 tube)
7. Tip sample holder 1 set
8. One metal mesh (into the combustion column)
9. 1 plastic outlet plate (already placed in the combustion tube)
10. Rubber hose 2
11. M10×1 inner joint screw 1 (within the combustion column)
12. M10×1 joint nut 1 piece (connected to the main unit)
13. Instructions 1 copy