Home /

M6 Terminal 12v 150ah Solar Gel Battery in Wind Power System

M6 Terminal 12v 150ah Solar Gel Battery in Wind Power System

Brand Name:FBATTERY
Certification:CE UL ISO9001 ISO14001 OHASA18001
Model Number:6GFM-150G
Minimum Order Quantity:Negotiable
Delivery Time:30Days
Payment Terms:T/T, D/P, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan Hubei China
Address: Room 316, Unit 3 Zhihui Building, 0601 Area of Jianhan, Economic Development Zone, Jianhan District, Wuhan, Hubei, China , Jianghan District, Wuhan, China
Supplier`s last login times: within 23 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

M6 Terminal 12v 150ah Solar Gel Battery In Wind Power System

Application of 12v 150ah Solar Gel Battery


Solar/Wind Power System
Uninterruptible Power Supplies (UPS)
Electric Power Systems (EPS)
Emergency Backup Power Supplies
Communication Power Supplies
DC Power Supplies
Auto Control System


Product Structure and Working Principle


Positive plate : Thick high Sn low Ca grid minimize corrosion and prolong life.


Negative plate : Balanced Pb-Ca grid for improved recombination efficiency.


Separator : Advanced AGM separator for ultra low float current.


Electrolyte : Dilute high purity sulphuric acid with nano gel.


Battery container and cover : ABS


Specification of 12v 150ah Solar Gel Battery


TypeGel Deep Cycle Battery
Nominal Voltage12V
Rated Capacity65Ah(10 Hr,10.8V,25℃)

Approx Dimensions(mm)
(Length×Width×Height)

L350mm x W166mm x H179mm
Cycle life≥3years
Approx Weight(kg)21kg
Applicable Temperature-40℃~60℃
Optimum Temperature20℃~25℃
Self-dischargeSelf-discharge rate<0.1% per day ( 20℃ )
Materials for Battery Containers and CoversABS
Screw Hole Size (mm)M6


Constant Currant Discharge Ratings-amperes at 25°C

F.V/Time5min10min15min30min1h2h3h4h5h8h10h20h
1.6V19514411973.243.925.518.414.712.28.356.893.71
1.67V17413311269.942.825.118.214.512.18.246.813.63
1.7V15512010667.341.824.718.014.312.08.146.723.54
1.75V13511298.265.040.924.317.714.211.88.036.633.48
1.80V11910291.662.139.623.817.413.911.57.846.503.41
1.85V10291.683.558.637.922.916.813.511.37.676.333.33


Constant Power Discharge Ratings-watts at 25°C


F.V/Time5min10min15min30min1h2h3h4h5h8h10h20h
1.6V34325921713581.947.934.827.823.316.113.37.20
1.65V31024120613080.247.434.627.723.216.013.27.09
1.70V28022119612678.947.134.427.623.115.913.16.99
1.75V24720818412377.946.734.227.523.015.813.06.89
1.80V22119117311876.046.133.827.122.615.512.96.81
1.85V19317415911373.544.733.026.522.315.312.76.70

Application Fields

Solar Power System, Wind Energy Storage System, UPS systems, switchgear, CATV and telecommunication systems applications, electric wheelchairs field, medical equipment field, washing machines field and so on.

Advantages

1. Long Life

VRLA gel type battery uses high-tin alloy positive grids and thick plates to reduce the utilization of active material. It has special additives. Its 40% DOD cycle life can reach over 3000 times as per the requirement of IEC 60896-22-2004.

2. Super Overdischarge Tolerance

After 5 times of over-discharges which cause the short circuit, battery capacity restoration can reach more than 95%.

3. High Cycling Ability

Special gel electrolyte additives, curing process at high temperature and high humidity are employed to delay the softening of active materiaI, therefore the deep cycle endurance is improved efficaciously, especially the anti-passivation (anti barrier layer) capability of positive plates during reaction when batteries are used for small load and small current discharge.

4. Excellent High-current Performance

Tighten assembly is designed to reduce distance of battery plates, to improvethe high current discharge performance.

5. Safety

The rubber 0-ring with strong corrosion resistance and the special adhesive are adopted to seal the terminals of the batteries, ensuring no acid leakage from the roots of terminals, and safe and reliabIe operation.

6. Maintenance Free

Since the design is of low liquid type, the gases generated inside the system is recombined into water; there is no need to add water or acid.

7. Various Installation Types

The special AGM separator can absorb the electrolyte thus there is no free acid inside the battery, therefore both verticaI and horizontaI positions are allowed when the batteries are to be mounted.

China M6 Terminal 12v 150ah Solar Gel Battery in Wind Power System supplier

M6 Terminal 12v 150ah Solar Gel Battery in Wind Power System

Inquiry Cart 0