6pcs Dental Files Root Canal Treatment Instruments With Heat
Activation
CM Gold Engine, NITI CM-Mire colorful taper File,root canal
instruments, ISO, used for dental
Specifications:
Taper | SX | .05 |
S1 | .03 | |
S2 | .04 | |
F1 | .07 | |
F2 | .08 | |
F3 | .09 | |
F4 | .06 | |
F5 | .05 | |
Torque | SX | 3.0 N/CM |
S1 | 3.0 N/CM | |
S2 | 1.0 N/CM | |
F1 | 1.6 N/CM | |
F2 | 2.0 N/CM | |
F3 | 2.0 N/CM | |
F4 | 2.0 N/CM | |
F5 | 2.0 N/CM | |
Rotary Speed Range | SX | 300-375 RMP |
S1 | 300-375 RMP | |
S2 | 300-375 RMP | |
F1 | 300-375 RMP | |
F2 | 300-375 RMP | |
F3 | 300-375 RMP | |
F4 | 300-375 RMP | |
F5 | 300-375 RMP | |
Size | SX | #19 |
S1 | #18 | |
S2 | #20 | |
F1 | #20 | |
F2 | #25 | |
F3 | #30 | |
F4 | #40 | |
F5 | #50 | |
ISO Color | SX | Yellow |
S1 | Violent | |
S2 | White | |
F1 | Yellow | |
F2 | Red | |
F3 | Blue | |
F4 | Yellow | |
F5 | Red | |
Using Times | SX | 15-18 times |
S1 | 18-20 times | |
S2 | 18-20 times | |
F1 | 15-18 times | |
F2 | 15-18 times | |
F3 | 15-18 times | |
F4 | 15-18 times | |
F5 | 15-18 times | |
Cross Section | Triangle |
Description:
Heat Activation is almost as the same as Topmost Gold in operation.
Heat Activation is also with special materials and processing
technology. It has advanced bending function and changes with the
temperature, especially in terms of fracture resistance, it is
currently in the international leading level.
Structure
1. Shaping Files(SX,S1,S2):Using SX to make the formation of crown
and short root canal, preparation the upper 1/3 root canal with S1,
S2 for middle 1/3 root canal preparation.
2. Finishing Files〈F1,F2,F3〉:All used for the formation of 1/3 root
canal tip.
Operation Sequence:
1. Establishing linear channel , cleaning the canal with sodium
hypochlorite
2. Detect the root canal Using #10, #15 SSK file
3. Makes the formation of crown with SX and create the canal path
(cleaning with Sodium Hypochlorite )
4. Preparation the upper 1/3 crown with S1 , flush canal with
sodium hypochlorite solution (STDN ) after getting it out
5. Using the same rotary method to the working length with S2 , and
flush canal with sodium hypochlorite solution (STDN )
6. Using F1 to the working length , which could make a smooth
connect between the 1/3 canal tip and middle 1/3 canal
7. F2 to the working length and using #25 K files to measure the
diameter of apical foramina , which indicating finished the
preparation and it could be filled if it is loose
8. Using the F3 to the working length if you didn't feel loose when
using the #25 K files.
Warning:
1.Only skilled dentists are allowed to use.
2. Be sure to sterilize this product for each use.
3. Do not use this product except for the dental service and
treatment. Use it in accordance with the intended use.
<Precautions for use>
1. To prevent infection, sterilize the product by autoclave and
make sure
sterilization is completed before using.
2. Choose the most appropriate type for each case and follow the
general
method.
3. Before using, make sure the instruments outside of dental cavity
that
there are no deformations, scratches and cracks.
4. If the head of product is thin, long or large, there are
possibilities for
breaking or twisting. Because of this, be sure to avoid using
unreasonable angle and excessive pressure.
5. Wear safety glasses to protect your eyes from damage. Also, wear
a
dust protective mask to prevent inhaling dust.
6. Wear rubber dam etc. to avoid accidental ingestion and falling.
7. Do not use this instrument for any purposes except for listed
applications above.
8. Only for use by dentists.
9. After using, follow an appropriate treatment as medical waste.
10. Dispose the product if damaged or contaminated.
11. After using, wash it with medical cleaning agent and brush,
then
wash away foreign substances like adherent body fluids and body
tissues.
12. Set the product to a stand when cleaned by ultrasonic cleaner
to avoid
working part deterioration.
13. Use this product with great care to avoid puncturing fingers
because
of its possession of sharp-edged part.
<Storages and duration of use>
1. Avoid storing at high temperature, humidity and direct sunlight.
Keep liquids away. Store it at room temperature.
2. Do not damage or make a pinhole to packaging materials.
3. Do not keep under germicidal lamp to avoid deterioration.
<Maintenances and inspections>
1. Sterilize this product by autoclave under established method and
term for each use.
Method of sterilization:
Put this product in a sterilization pack or (or foil) and place it
on a
sterilization tray, or files stand for autoclave sterilization with
reference to the following terms.
Terms for sterilization:
term(1) temperature: 121degrees Celsius time: 20 minutes or more
term(2) temperature: 126degrees Celsius time: 15 minutes or more
2. Do not use high pressure steam sterilizer which heats more than
200
degrees Celsius including drying process.
3. When reusing the instrument, wash away foreign substances
completely and sterilize.
4. Regarding use of medical cleaning agent, follow the instruction
manual by its manufacturer strictly.
5. Dispose the product if damaged or decreased in performance
Packages
1. Minimum packaging unit: 6 pcs. /package
(SX,S1,S2,F1,F2,F3,F4,F5)
2. Assortment: 1 pc. from each size/package (SX-F3)
Legal Manufacturer
SHENZHEN FEIHUAN MEDICAL INSTRUMENTS CO., LTD
Add:1305,Wensheng Center,Wenjin Sq.,Tianbei 1st Rd., Luohu Dist.,
Shenzhen, China, 518000
Tel:+86-755-28540953 Fax:+86-755-28540953
EU Representative
Well Kang Limited
The Black Church, St.Mary's Place, Dublin 7, Ireland
Applications:
Dental Root Canal Treatment | Hospital , Clinic , lab... |
Competitive Advantage:
1, Eliminating Root Canal perforation
2, Improving 300%-500% Fracture Resistance
3, Optimizing recovery of Unique NITI CM-Wire Material