Single Use Medical Surgical Instrument Stapling For Surgical Operation

Brand Name:Qianjing
Certification:CE, ISO13485
Model Number:QMBE
Minimum Order Quantity:Negotiation
Payment Terms:T/T, L/C, D/A, D/P, Western Union
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Changzhou Jiangsu China
Address: No.6 Fengming Road, Wujin Hi-tech Industrial Development Zone, Wujin District, Changzhou, Jiangsu, China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

Single Use Medical Instrument Surgical Stapling Endo Cutter Stapler for Surgical Operation

Product Name
Disposable Endo Cutter Stapler and Reload


Specification

Product NameSpecificationStaple Height (mm)Suturing Length (mm)Staple Quanlity (pcs)Color
Disposable Endo Cutter StaplerQLCE-I////
QMBE-II////
Disposable Endo Cutter Stapler Reload (Straight)QMBEC-30C2.53142White
QMBEC-45A4.84666Black
QMBEC-45B3.8Purple
QMBEC-45C2.5White
QMBEC-45E3.4/3.6/4.0Purple
QMBEC-45F4.4/4.6/4.8Black
QMBEC-45S2.4/2.6/3.5White
QMBEC-60A4.86190Black
QMBEC-60B3.8Purple
QMBEC-60C2.5White
QMBEC-60E3.4/3.6/4.0Purple
QMBEC-60F4.4/4.6/4.8Black
QMBEC-60S2.4/2.6/3.5White
Disposable Endo Cutter Stapler Reload (Curved)QMBEL-30C2.53142White
QMBEL-45A4.84666Black
QMBEL-45B3.8Purple
QMBEL-45C2.5White
QMBEL-45E3.4/3.6/4.0Purple
QMBEL-45F4.4/4.6/4.8Black
QMBEL-45S2.4/2.6/3.5White
QMBEL-60A4.86190Black
QMBEL-60B3.8Purple
QMBEL-60C2.5White
QMBEL-60E3.4/3.6/4.0Purple
QMBEL-60F4.4/4.6/4.8Black
QMBEL-60S2.4/2.6/3.5White

Application
Suitable for open or endoscopic surgery , the lungs , bronchial tissue and gastrointestinal surgery and so on.

Surgical Staping Description
1. Brand new knife blade for each single use loading unit to provide the sharpness and ensure complete tissue cutting, reduce tissue damage.
2. Six rows of staple lines for both tissue ,provide 3 kinds of staple height to make sure the safety of anastomosis and closure , avoid bleeding.
3. One handle is versatile for all sizes reloading.

Contraindication
1. The tissue has inflammation, edema or tumor.
2. The tissue is so thick (two layers of gastrointestinal wall, when compressed, is estimated to be more than 2.5~3mm) that the stapler cannot penetrate it.
3. The tissue is so thin that putting in the stapler may tear it.
4. In principle, it is inappropriate for mechanical suturing again if the first one fails.


Product Photoes

China Single Use Medical Surgical Instrument Stapling For Surgical Operation supplier

Single Use Medical Surgical Instrument Stapling For Surgical Operation

Inquiry Cart 0