Water Chiller Refrigeration Shell and Tube


Evaporator Heat Exchanger


Water-cooled screw chillers are mainly composed of semi-enclosed screw compressors, shell and tube


condensers, dry filters, thermal expansion valves, shell and tube evaporators, and electrical control parts.


Unit cooling, the compressor will evaporator low temperature and low pressure refrigerant into the


cylinder, through the compressor work, refrigerant vapor is compressed into high temperature and high


pressure gas,


Through the exhaust pipe into the condenser. The high temperature and high pressure refrigerant gas


exchanges heat with the cooling water in the condenser, transfers heat to the cooling water, and the


refrigerant gas condenses into the high pressure liquid.


The high pressure liquid from the condenser is throttled by the thermostatic expansion valve and enters


the evaporator.


In the evaporator, the low-pressure liquid refrigerant absorbs the heat of the chilled water and vaporizes


the chilled water to cool down and becomes the required low-temperature water.


After the vaporization of the refrigerant gas is re-compressed by the compressor to be compressed,


discharged into the condenser, so that the cycle, the continuous cycle, in order to achieve the cooling of


chilled water.


From the unit out of chilled water, into the indoor fan coil, variable air volume air conditioner and other


end devices in the indoor and convective air heat exchange, in the process, the water due to the


absorption of indoor air heat (to the indoor air heat) And the temperature rises, and the indoor air after


the indoor heat exchanger after the temperature drop, driven by the fan, into the room, thereby reducing


the indoor air temperature, and the temperature rise after the chilled water in the role of the pump re-


enter the unit, so Cycle, so as to achieve the purpose of continuous cooling.


U SHAPED TUBE DRY EVAPORATOR (SINGLE CIRCUIT)


CAPACITY: 120KW TO 270KW


ModelsQXU120S8QXU135S8QXU155S8QXU185S10QXU220S10QXU270S10

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW120135155185220270
Kcal/h(×103 )103.2116133.3159180232
Wnm3 /h20.323.226.731.837.846.4
Wmm3 /h252830414365
Dpnbar0.410.440.370.360.430.42

ModelsQXU120S8QXU135S8QXU155S8QXU185S10QXU220S10QXU270S10
Dimension(mm)A181521152315232026542654
B219219219273273273
C180180180200234234
D153018302030200022802280
E240240240300300300
VentS11/21/21/21/21/21/2
OutletS21/21/21/21/21/21/2
ConnectionW(DN)808080100100100
D1(mm)353535353535
D2(mm)545467678080
P(kg)145155163232279289

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature


U SHAPED TUBE DRY EVAPORATOR (SINGLE CIRCUIT)


CAPACITY: 18KW TO 95KW


ModelsQXU18S5QXU28S5QXU35S6QXU47S6QXU56S6QXU65S6QXU80S8QXU95S8

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW18.628.235.14756658095

Kcal/h

(×103 )

162430.240.448.256.768.881.7
Wnm3 /h46689.611.413.816.4
Wmm3 /h6.381011.41214.51821
Dpnbar0.160.290.270.410.350.390.420.46

ModelsQXU18S5QXU28S5QXU35S6QXU47S6QXU56S6QXU65S6QXU80S8QXU95S8
Dimension(mm)A8871037127514071431143116311781
B140140168168168168219219
C9797107107161161161161
D690840104011901030118013801530
E180180200200200200240240
VentS11/21/21/21/21/21/21/21/2
OutletS21/21/21/21/21/21/21/21/2
ConnectionW(DN)4040505065656565
D1(mm)2222222222222222
D2(mm)3535353554545454
P(kg)495872788893125136

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature


CONDENSER SERIES SINGLE CIRCUIT


CAPACITY: 20RT TO 35RT


ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
DT1TACE
QXC20S8207.560219127013809023811311015.8
QXC25S8259.4502191600171012023811312119.5
QXC30S83011.3402191600171012023811313423
QXC35S83513.2302191600171012023811314027.3

ModelS (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)W (optional port)
FPT(inner pipe thread)FPT(inner pipe thread)FPT(inner pipe thread)
QXC20S81/41-1/87/82-1/22
QXC25S81/41-1/87/82-1/22
QXC30S81/41-3/81-1/82-1/22
QXC35S81/41-5/81-1/82-1/22

CONDENSER SERIES SINGLE CIRCUIT


CAPACITY: 40RT TO 60RT


ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
DT1TACE
QXC40S104015.12273160017501202738517231
QXC45S104517.01273160017501202738518035
QXC50S105018.90273203221821202738520938.5
QXC55S105520.79273203221821202738521742.5
QXC60S106022.68273203221821202738522446

ModelS (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)W (optional port)
FPT(inner pipe thread)FPT(inner pipe thread)FPT(inner pipe thread)
QXC40S103/81-5/81-1/832-1/2
QXC45S103/81-5/81-1/832-1/2
QXC50S103/81-5/81-1/832-1/2
QXC55S103/81-5/81-3/832-1/2
QXC60S103/81-5/81-3/832-1/2