ISO9239-1 Flooring Radiant Heat Flux Fire Testing Equipment

Brand Name:SKYLINE
Certification:CE
Model Number:SL-FL086
Minimum Order Quantity:1 unit
Delivery Time:20 working days
Payment Terms:T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No.1802 Room 6# Building Universal Commerce Center Nancheng District Dongguan Guangdong China
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

Building Materials Flammability Tester Radiant Flooring Panel Apparatus

Application

Critical Radiant Flux is the main parameters of the fire risk for flooring materials, it reflects the burning and spreading ability of flooring material specimen under external heat radiation conditions. It is an important index of combustion classification for building products.

According to ISO9239-1,2 and GB/T 11785-2005 requirements, ISO 9239-1 Flooring Materials Radiant Analyzer with Good Price is measuring the critical radiant of combustion floor coverings, through the radiation environment of test chamber. It is can also be used to measure the critical radiation of the cellulose insulation floor material. Specimen is located at down horizon of 30 degree sloped gas radiation panel per horizon surface.

Features

1. Blower for gas supply of radiant plate can supply gas continuously, while air compressor supply gas uncontinuously.
2. Heat Flux meter, portable water cooling system without running water supply.
3. Ventilation hood of stainless steel on the top of the chamber.
4. Inner chamber of Heat and corrosion resistant Aluminum silicate plate.
5. Heat resistant honeycomb ceramic thermal radiant plate 300mmX450mm, inclined at 30 degree.
6. T-shape porous burner with auto ignition system ignites the specimen with automatic push system.
7. Gas control board. Needle valve control the height of burner flame, MFC controls the gas flux and digital display.
8. Inverter control blower output, ventruri control the proportion of air and gas, and flame is stable, and accurate.
9. porous calibration apparatus: adjust radiant plate output by turning upward, left or right.
10. IR radiometer shows the temperature of the radiant plate.
11. Optional smoke density testing system.
12. Optical system 2900 ± 100 K light advanced optical signal receiver.
13. integrated design with 19" PC of Lab view software.
14. Chimney with1pc thermocouple, and 1pc thermocouple inner Chamber controlled by software.

Standards

ISO 9239-1 reaction to fire test of flooring material, Part 1, measure the combustion performance of flooring material with radiant heat.
ISO 9239-2 reaction to fire test of flooring material, Part 2, measure the horizontal spread of flame, exposed to 25kw/m2 heat flux.
ASTM E 648 Standard test method for flooring covering system CHF with heat radiant energy source.
ASTM E 970 Standard test method for flooring material CHF of exposed attic floor insulation using heat radiant energy source.
NFPA 253 Standard test method for CHF of floor covering system with heat radiant energy source.
DIN 4102

Specification

Dimension testing chamber2220(W)×1500(D)×2650(H)mm
Control chamber600(W)×600(D)×1600(H)mm
Gas control chamber600(W)×600(D)×1000(H)mm
PowerAC 220V, 50/60Hz, 25A
Weight220kg
Air supply option propane95%

Test Report

Report
Testing agency 
Standard 
Operator Test date 
Ambient temperature Environment humidity 
Equipment deadline 
Product name Sample serial number 
Model specification 
Sample size Device Code 
Material density (g/㎡) Test time(s) 
Debug balance 
Test Results:
Distance (mm)Flame front end time(s)Distance(mm)Flame front end time(s)
60 560 
110 610 
160 660 
210 710 
260 760 
310 810 
360 860 
410 910 
460 960 
510 1100 
The front end of the flame reaches the longest distance (cm) Critical radiant flux(kW/m2) 
Total smoke value(%.min) Maximum absorption rate(%) 
10min flame front end reach distance(mm) 10min critical radiant heat value(kW/m2) 
20min flame front end reach distance(mm) 20min critical radiant heat value(kW/m2) 
30min flame front end reach distance(mm) 30min critical radiant heat value(kW/m2) 
Ignition time(s) Flame extinction time(s) 
The phenomenon observed during the test: 

Critical Radiant Flux Flammability Testing Equipme...

China ISO9239-1 Flooring Radiant Heat Flux Fire Testing Equipment supplier

ISO9239-1 Flooring Radiant Heat Flux Fire Testing Equipment

Inquiry Cart 0