Add to Cart
The International Electrotechnical Commission IEC 60754 Part 1 and
Part 2 test is performed to determine the degree of acidity of
gases evolved during the combustion of materials taken from
electric cables by measuring the pH & conductivity.
IEC 60754-1 is halogen-free cable came from and including the
polymer to halogenated compounds on the basis of the additive
compounds emitted during combustion, except the fluoridation
hydracids, it is measure for gas of halogen volume, IEC 60754-2 for
electrical or optical cable from compounds emitted during the
combustion of measure the gas of oxidation limit.
1.1200°C Split-Hinge Tube Furnaces for horizontal use.
2.Heating element modules for superior radial and linear
temperature uniformity and fast heat up and cool down.
3.Long-life, energy-efficient elements require little or no
maintenance.
4.Mode conversion switch (Test method of IEC 60754-1&2 could be
selected).
5.Alarm Temperature Controller: Temp controller to protect
overheating of furnace.
6.Quartz work tube and sample lading assembly.
7.pH and conductivity measuring instruments with digital display
and electrodes Stirrer.
8.Mass flow meter control the flow rate of air and digital display.
9.Activated Charcoal (air filtering): Filter for filtering the
supplied air (activated charcoal).
10.Silica Gel (air drying): Device for drying the supplied air.
11.100 ceramic sample boats.
1. The mass flow meter adjusts the air flow, the range is 0-3L/min,
and the air flow is numerically displayed, and can be precisely
adjusted, and the adjustment precision is 0.1L/min;
2.Equipped with air filter device, containing 1 activated carbon
and silica gel filter column;
3. Including two temperature control modes, one is the temperature
programming mode, the other is the single-point heating mode, all
adopt PID temperature control mode, the user can choose according
to the test;
4. Over-temperature protection device, when the temperature of the
tube furnace exceeds 1100 degrees, the heating can be automatically
cut off to protect the furnace body;
5. Openable tube furnace device, easy for users to clean and
replace the quartz heating tube;
6. Using imported thermoelectric tube furnace device, with
excellent product performance and longer product life;
7. It is equipped with auxiliary devices such as magnetic stirrer,
PH meter and conductivity tester.
Corrosion Test Apparatus, designed and manufactured according to the test method GB/T 17650, IEC 60754-1/2, used to test the content of halogen gas released during the combustion of wire and cable, pH (hydrogen ion content), conductance Rate, etc., can be extended to EN 50305 and BS 6853 Appendix B, smoke toxicity test, in line with standards: GB/T 17650.1~2-1998, IEC 60754-1/2-1994, EN 50305, BS 6853 Appendix B, etc. standard test.
Standards:
IEC:IEC 60754-1&2: 2011
GB/T 17650-1&2:1998
Dimension:
Dimensions: 889 mm (W) X 432 mm (D) X 406mm (H)
Control Unit: 430 mm (W) × 370 mm (D) × 320 mm (H)
Weight:76kg
Installation requirements
Electrical: 110V AC 60Hz / 230V AC 50Hz, 15A
Ambient Temperature: Operating 10°C to 35°C