BS 8414-1 Fire - Proof Test For Outer Wall External Thermal Insulation System

BS 8414-1 Fire - Proof Test For Outer Wall External Thermal Insulation System

Brand Name:SKYLINE
Certification:CE
Model Number:SL826
Minimum Order Quantity:1 UNIT
Delivery Time:45 work days
Payment Terms:T/T, Western Union,paypal
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No.1802 Room 6# Building Universal Commerce Center Nancheng District Dongguan Guangdong China
Supplier`s last login times: within 14 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Fire-Proof Test For Outer Wall External Thermal Insulation Systen


Product introduction

The window fire test model simulates a vertical building surface consisting of a main wall and a vertical auxiliary wall.

The external thermal insulation system is installed on the building surface. The opening of the combustion chamber at the bottom of the test model simulates the windows or openings of the floor in the actual building. The ignited wood or gas flame overflows from the window to simulate the fire after ignition in the room. When a flame overflows from a window or hole, it attacks the external thermal insulation system, checks the damage degree of the external thermal insulation system, and judges its flame propagation. The total heat released in 30 minutes is about 4500 MJ, and the peak heat release rate is about (3 + 0.5) MW.

Standard : BS 8414-1:202 / GB/T 29416:2012


Performance characteristics

1. The test system provides the ignition alarm after 5 minutes. When ignited, the test start time can be automatically determined. At the same time, the test overtemperature can be automatically distinguished. At the same time, the computer can display combustion test by visual frequency. At the same time, computer software can record dropping time, collapse time, temperature value and display temperature curve and other test related information.

2. One wind speed sensor, 0-10M/S, with an accuracy of 0.1M/S;

3. Two cameras, including a computer display device 2.

4. K-type thermocouple: with stainless steel sheath, the temperature range is 0-1038 degrees, the temperature accuracy is (+0.1%) and the thermocouple wire is 500 feet.

5. ADAM-4118 Module: Strong 8-way Thermocouple Input module, 8-way independently configurable differential channel; Wide temperature operation; Wider operating temperature: -40-+85 degrees C; High noise resistance: 1KV surge protection voltage input, 3KV EFT and 8KV ESD protection; Strong anti-interference: 1KV surge protection at power input, 3KV EFT, 8KV ESD protection, wide. Power input range: +10~+48 VDC; input range: +10~+48 VDC;

6. Two computers;

7. Three electronic control boxes;

8. One signal conversion box;

9. Field wiring.


Electrical requirements: 220V, 50HZ, 5A

environmental requirements: temperature from 10°C to 35°humidity (65 ± 5) %

Application : building materials