Use
Use Simulated match flame fire source to evaluate the anti-ignition characteristics of soft furniture.
Standard
ISO8191-1~2:1988, EN597-1~2:1995
Technical Parameters
1, Simulated match flame
1.1. Ignition source system: stainless steel combustion tube, one
inner diameter (8±0.1mm) inner diameter (6.5±0.1mm) length
(200±5mm), two sets
1.2. Hose: the length should be (2.5 ~ 3mm) and the inner diameter
should be (7 ± 1mm) connected to the stainless steel combustion
tube
1.3. Flow Control System: Includes a flow meter, trim valve, on-off
valve, and pressure regulator.
1.4. The flow rate is (45 ± 2) m1/min. The nominal output pressure
provided by the system is 2.8kpa.
1.5. Timing range: 0-999S, can display and record the time of
continuous burning or smoldering, fabric cracking time, test piece
extinguishing time,
1.6. Test distance of igniter: 20-80 adjustable, with automatic
movement and evacuation of ignition mechanism 7. Flow measurement
range: 10~100m1/min
2, Smoldering cigarette
2.1 cigarette ignition source
2.2 Cigarettes are cylindrical cigarettes with a filter or with a
filter and interface package removed, and meet the following
requirements:
Length: 60 ± 5mm;
Diameter: 8±0.5mm;
Mass per unit length: (0.6 ± 0.1) g / 50 mm;
2.3 Cigarette burning time: (12 ± 3) min / 50mm.
2.4 In the same cigarette, each group of 10 is selected from one of
them, and the burning time of the cigarette is measured in the
laboratory according to the following method: after the cigarette
is pretreated according to 7.1, one is taken out, and the cigarette
is separated from the cigarette. The ignition end is marked with
5mm and 55mm at each end. Insert the non-ignition end of the
cigarette horizontally into a fine steel needle with an insertion
length of no more than 11 mm. The ignition end is ignited in
accordance with 8.2 and the test records the time it takes for the
cigarette to burn between the two marks.
3, Laboratory: 2.5 meters long, 2.2 meters wide, 2.5 meters high,
with ventilation ducts. Made of stainless steel.
3.1 Observation window: one large observation window of tempered
glass, surrounded by SUS304 stainless steel
3.2 Gas flow regulation: adjust the test gas flow rate to 45 ± 2mL
/ min.
3.3 Timing: 0-99.99H/m/s arbitrarily set
3.4 Control System:
3.4.1 Computer control system, (test time, number of tests, flame
retarding time, etc. can be set and recorded in the computer. With
high intelligence, guided menu operation, simple and intuitive
features, the test results are more accurate.
3.4.2 Automatic ignition function (for high voltage electronic fire).
3.4.3 Adopt PLC mode, all adopt high-quality devices to ensure
high-quality system and high-speed operation, and advanced. It
adopts the imported PLC+PID automatic control mode test process,
which is the most advanced, safest, most reliable and most
convenient control method. Realize automatic detection and control,
auto-complete detection, and friendly and friendly display
interface, making inspection work faster and more accurate. The
upper computer adopts configuration software design, which can
automatically generate temperature control curve and report output.
Data acquisition and print test results
3.4.4 Computer: One.
3.4.5 One printer
3.4.6 software set, free upgrade for life