Product Details
Over-current Flammability Testing Equipment For Wires and Cables Resistance to Fire
Application
Applies to check the test integrity of the circuit for wires or cables, use to check the flame retardant properties of insulating refractory characteristics of cable and wires and cables with fireproof layer under overheating, over-current, etc abnormal condition.
Standards
According to IEC60331-11:19999, IEC60331-21:1999, IEC60331-23:1999, IEC60331-25:1999, and BS6387
Technical parameters
Ribbon burner500m for length of nozzle, 15mm for width of nozzle. Number of the hole of 1.32mm diameter is totally 470
Gas flow range1-10L/min; glass rotor flow meter indicates the current flow, Using propane gas or liquefied petroleum gas (LPG)
Area flow range10-100L/min, glass rotor flow meter indicates the current flow
Position of burnerBurner center horizontal at 70±10mm under the specimen lowest point, nozzle at 45mm distance from the specimen center vertical
Specimen supported150mm for inner diameter of metal ring, using 12mm stainless steel materials.NO:5
ThermocoupleK type thermocouple with stainless steel sheathed, which diameter is 1.5mm and according to GB/T 16839.1
Temperature calibration2pcs of thermocouples display data average value between 750+50-10℃required in 10 minutes, and difference value between average value and either of the two thermocouple’s display data cannot over the 40℃
Test powerOutput voltage is AC0~1000V and output current is AC0.01-0.70A, four circuits adjustable independent
Burning time0~999.9S/ M/H adjustable
Laboratory27m3