4KW 220VAC Rack Mount Load Bank for Data Center Commissioning Testing


Introduction:


AC Dummy Load Bank offers the most robust, high-capacity designs in the industry. AC Testing Dummy Load Bank is setting the standard with intelligent operator controls, safety indication layouts, adjustable load step resolution, and lightweight designs. AC Testing Dummy Load Bank is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems.


Main Features:


1.Designed for use in Ambient Temperature Upto 55 degree;


2. Push buttons for energizing and de-energizing loads with indication;


3. Multiple control mode: (1) manual panel control (2) remote control (3)software control


4. Multiple display function: voltage, current, frequency, power factor, active power, reactive power, apparent power etc;


5. Forced air cooling: industrial heavy duty fan, horizon air intake, upwards outlet, low noise.


Our advantage


(1) Professional load bank direct factory;


(2) Advanced production line with skilled workers;


(3) Adopt International quality standards, to meet high quality requirement;


(4) Good reputation for Reliable Quality & Reasonable price.


Specification
Rating voltage220VAC
Max Load PowerPower:4kW
Load ResolutionStep:120W
Power Factor1
Load Tolerance±5%
Fan Control Power110V/220V,50Hz/60Hz
Wire ConnectionLoad bank input——Copper bar
Control power input——Connector-bar
Max Protection GradeIP32
Way of WorkingContinuous Working
CoolingForced air cooling, horizontal inlet air and upwards exhaust cooling
TransportationHoisting
ColorRAL7032
Dimensions485*177*500
Weight12.5KG
AccessoriesSwitch: ABB, Siemens and Schneider, PLC: Panasonic and Siemens;
Operating Environment Parameter
Ambient Temperature-10℃~+50℃
Relative Humidity≤95%