Endoscopic Surgical Ligating Clip Applier For Polymer Ligation Clip Firing Use

Brand Name:New Life
Certification:ISO, CE,FDA
Model Number:S,M,L
Minimum Order Quantity:10pcs
Delivery Time:10days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang
Address: 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

Endoscopic Polymer Ligation Clip Applier

Description


Endoscopic Ligating Clip Appliers are designed for use as delivery devices for Polymer Ligating Clips. Clip appliers are reusable instruments that manually load and deliver one clip at a time.


Mannual

  • Always check applicator’s mouth alignment before using.
  • When closed, the ends of the mouths should be aligned and aligned with each other.It is very important to align the mouth for safe application of the clip. If this is not done, the patient may be harmed. Regular maintanence , care and cleaning are required to ensure proper functionally.
  • This applier is NOT designed for use with an operative cannula fort he purposes of maintaning pneumoperitoneum. Proceed carefully when inserting the instrument through cannula. Do NOT apply lateral pressure on the applier as damage to the working tip may occur.
  • Before use, examine the instrument for bent,broken,cracked or worn parts. In order to avoid unnecessary gas loss, ensure the cleaning port cap fits tigthly on the Luer – Lock flush port. A spare cap is provided for your convenience.
  • Always confirm that the clips remains in the applier after insertion of the applier and clip through a cannula. Do not attempt to close the jaws on a vessel or anatomic strucuture without a clip properly loaded into the jaws.Closure of empty jaws on a vessel or anatomic structure may result in patient injury.
  • Rotation knob should only be avtivated with jaws in open position. Failure to do this may result in damage to the applier.

Loading Instructions

1. Pay attention to colour-coding. Choose the proper applier corresponding in colour with the clips cartridge. The colour indicates the clip size.

2. Use the proper grip of the clip applier.Applier jaws should to be positioned perpendicularly to the cartridge body.

3. Note that the applier jaws must enter the cartridge simultaneously.Properly position the triangular marker situated on the side of the cartridge to ensure good visibility of the clip during application.

4. Verify that the clip loading/seating is correct .


Key features

- Handle available for Medium + Medium-Large and Large + Extra-Large shafts,

- jaws activated by front handle for better stability,

- 360° shaft rotation by index finger allows one-handed operation,

- flushing port facilitates easy cleaning of the shaft, thus eliminating potential contamination,

- detachable design for greater versatility and cost savings,

- made of high quality stainless steel,

- colour coded size matching cartridge hue,

- compatible with corresponding sizes of polymer non-absorbable clips