Home /

Fecal Occult Home Blood Test Kit 4mm Cassette Colorectal Cancer Detection

Fecal Occult Home Blood Test Kit 4mm Cassette Colorectal Cancer Detection

Brand Name:New Life
Certification:ISO13485,
Minimum Order Quantity:5000pcs
Delivery Time:20-30days
Payment Terms:T/T, Western Union
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang
Address: 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China
Supplier`s last login times: within 37 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

High Accuracy Fecal Occult Blood Home Testing kits, 4mm cassette, Detection of Colorectal cancer at home


Product Name: One Step Fecal Occult Blood Fecal Occult Blood Home Testing kits


Summary:


Many diseases can cause hidden blood in the feces. This is also known as Fecal Occult Blood (FOB), Human Occult Blood, or Human Hemoglobin. In the early stages, gastrointestinal problems such as colon cancer, ulcers, polyps, colitis, diverticulitis, and fissures may not show any visible symptoms, only occult blood. Traditional guaiac-based methods lack sensitivity and specificity, and also have diet restrictions prior to testing.The FOB Rapid Test Cassette (Feces) is a rapid test to qualitatively detect low levels of Fecal Occult Blood. The test uses a double antibody sandwich assay to selectively detect Fecal Occult Blood at 50ng/ml or higher, or 6μg/g feces. In addition, unlike guaiac assays, the accuracy of the test is not affected by the diet of the patients.


INTENDED USE:The FOB Rapid Test Cassette (Feces) is a rapid chromatographic immunoassay for the qualitative detection of Human Occult Blood in feces.


QUALITY CONTROL


Internal procedural controls are included in the test. A colored line appearing in the control region (C) is an internal valid procedural control. It confirms sufficient specimen volume and correct procedural technique.

Control standards are not supplied with this kit; however, it is recommended that positive and negative controls be tested as a good laboratory practice to confirm the test procedure and to verify proper test performance.


TEST PROCEDURE


1. Bring the pouched test device to room temperature (15-30℃) prior to testing. Do not open the pouch until ready to perform the assay.
2. Remove the test device from the sealed pouch.
3. Specimen collection. Please see “SPECIMEN COLLECTION AND STORAGE”.
4. Shake the sample collection tube well.
5. Holding the sample collection tube upright, carefully break off the tip of collection tube.
6. Squeeze 3 drops of sample solution into the sample well “S” .
7. Read results between 5-10 minutes. Do not read results after 10 minutes.




Limitation


  1. The FOB Rapid Test Cassette (Feces) is for in vitro diagnostic use only.
  2. The FOB Rapid Test Cassette (Feces) will only indicate the presence of Fecal Occult Blood, the presence of blood in feces does not necessarily indicate colorectal bleeding.
  3. As with all diagnostic tests, all results must be considered with other clinical information available to the physician.
  4. Other clinically available tests are required if questionable results are obtained.

PERFORMANCE CHARACTERS:


The FOB Rapid Test Dipstick (Feces) has been compared with another leading commercial rapid test using clinical specimens.


MethodOther Rapid TestTotal Result

FOB Rapid Test Dipstick

(Feces)

ResultsPositiveNegative
Positive1894193
Negative10802812
Total Result1998061005

Relative sensitivity: 95.0% (95%CI*: 91.0%~97.6%);

Relative specificity: 99.5% (95%CI*: 98.7%~99.9%);


Accuracy: 98.6% (95%CI*: 97.4%~99.0%). *Confidence Intervals


Sensitivity


The FOB Rapid Test Dipstick (Feces) can detect levels of Fecal Occult Blood as low as 50 ng/mL or 6 μg/g feces.


Cross-reactivity


The FOB Rapid Test Cassette (Feces) is specific to human hemoglobin. Specimens containing the following substances were diluted in the extraction buffer to a concentration of 1.0 mg/ml, and tested on both positive and negative controls with no effect on test results: Bovine hemoglobin, Chicken hemoglobin, Pork hemoglobin, Goat hemoglobin, Horse hemoglobin, Rabbit hemoglobin and Turkey hemoglobin.


ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry
China Fecal Occult Home Blood Test Kit 4mm Cassette Colorectal Cancer Detection supplier

Fecal Occult Home Blood Test Kit 4mm Cassette Colorectal Cancer Detection

Inquiry Cart 0